User Manual

Flash Memory installed (if any) is shown. If the Animation Data Flash Memory isn't
found, then 'not found' will appear in this space at the top of the screen.
To redraw the screen at any time, just press the <ESC>ape key or <SPACE> bar.
All numeric values are entered in HEXadecimal (0-9, A through F) or Decimal num-
bers (0-9), as selected on the menu. Each number consist of one or more ASCII charac-
ters followed by a <RETURN> (<ENTER> on some keyboards). If more characters have
been entered before the <RETURN> than are allowed, then the characters already en-
tered will scroll to the left to make room for the new entries. Once a command has been
invoked, characters can be erased one-by-one by using the <DELETE> key (<BACK-
SPACE> on some keyboards). An entire entry can be erased by hitting the <ESC>ape
key. A command can be canceled altogether by hitting the <RETURN> key (<ENTER>
on some keyboards) or <ESC>ape key after all the characters have been erased or be-
fore any have been entered.
Once you have configured a Br-ANA, you can ʻlockʼ the configuration by moving the
ʻWrite Protectʼ switch to the ʻWrite Protectedʼ position from the ʻWrite Enabledʼ position.
This should protect your configuration from anything short of a lightning hit. The menu
will change to show that the Flash Memory has been protected and warn you that you
Gilderfluke & Co., Inc. - BR-ANA Analog Card - version 4.10 - copyright 2012 DCM
Shows: 8, Ch: 123 @___0, ADL: AutoDownload_Filename
Serial Address- __0
__1 Show_FileName.sho looping @ frame ____1363
inputs: a/green: Y | b/red: Y MSB E minimum maximum "forced" PowerOn
c/blue: Y | d/white: Y address I scale scale position default
a) 1st addr: __0 (Autodownload) 0 (0) |_|____0__|__255__|_______|____0__|
b) twelve bit resolution- no -> 1 (1) |Y|____0__|__255__|_______|____0__|
c) sequencer enabled- yes 2 (2) |Y|____0__|__255__|_______|____0__|
d) DMX: Tx & Rx wo/CS, ^d) 1-based 3 (3) |Y|____0__|__255__|_______|____0__|
e) auto EaseIn- 1.00 seconds 4 (4) |Y|____0__|__255__|_______|____0__|
f) numbering- decimal/millisecond 5 (5) |_|____0__|__255__|_______|____0__|
6 (6) |_|____0__|__255__|_______|____0__|
j) address to test & adjust- __1 7 (7) |Y|____0__|__255__|_______|____0__|
k) test output- none 8 (8) |Y|____0__|__255__|_______|____0__|
FigureName 9 (9) |Y|____0__|__255__|_______|____0__|
OutputName 10 (A) |Y|____0__|__255__|_______|____0__|
11 (B) |Y|____0__|__255__|_______|____0__|
u) set min/max/forced using keypad 12 (C) |Y|____0__|__255__|_______|____0__|
q) force output to a value 13 (D) |_|____0__|__255__|_______|____0__|
t) set PowerOn defaults 14 (E) |_|____0__|__255__|_______|____0__|
w) set analog endpoints 15 (F) |_|____0__|__255__|_______|____0__|
n) Next, l) Last, i) info, o) def., p) looP, h) Halt, r) save, v) Verify, x) Xit
Command-
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Br-ANA Manual / December 18, 2012 10:21 AM / page 33 of 60