User Manual

c)! Entering a value as the default value for the currently selected output.
The PowerOn value for all outputs is displayed in the 'PowerOn Default'
column on the display.
W)Set Analog Endpoints:
This command is used to adjust the endpoints of the sixteen analog out-
puts. The ʻSet Min/Max/Forced using Keypadʼ is a much easier way of set-
ting these values. Use it if you can.
The analog outputs normally sweep between 0 and 10 Volts DC. By using
these commands you can set either endpoint to anywhere between 0 and 10
volts for a reduced or reversed analog output swing. If you want to invert the
voltage swing of any output, all you need to do is set the lower limit to a
higher level than the upper limit. The endpoints for all sixteen outputs is dis-
played in the 'Minimum Scale'/'Maximum Scale' columns on the display.
As an example of the use of the analog endpoint adjustments, if you
wanted to set the voltages on a channel to sweep from 2.5 volts to 7.5 volts:
Looking at the chart at the end of this manual, you can see that this would
be from approximately 25% to 75% of full scale. From the chart you would
see that the values that should be entered would be 64 (40h) and 192 (C0h).
To set the endpoints, first clear the endpoints to the two extremes (0%/0/
00h). Then use a Togglodyte, Programming Console, or the 'Force Output to
a Value' command to find what values set the proper endpoints for the out-
put. You can then enter these numbers into the endpoints for this output.
The endpoints can only be set for the on-board 0-10 volt analog outputs.
A new output address will be requested if the currently selected 'Output to
Test & Adjust' is not one of the on-board ones.
N) Next:
This moves the ʻOutput to test & Adjustʼ arrow down by one line.
L) Last:
This moves the ʻOutput to test & Adjustʼ arrow up by one line.