User Manual

You can define any of the inputs to any of the binary bits zero through
seven. Each of the binary bits should only be used once.
When any of the inputs that are assigned as a binary bit changes, the en-
tire binary byte is scanned. If the result is non-zero, the binary value is used
to select and play a show. Care must be taken that all the binary bits are
switched simultaneously. Some PLCs have an output update rate which is
slower than the Br-ANAʼs input scan rate, which can result in unexpected
shows being selected and played.