Owner manual

configured to pause the currently running show on a closure on this input
5
.
When a show is 'continued', the signal is dropped on the Green ʻPauseʼ
Output to the Smart Brick Brain. This input must be configured to continue
the currently running show on an opening on this input.
Once a show has been paused, the only two ways to 'continue' a show
are to:
a) Send an active signal from the Smart Brick System to the Kp-
300ʼs Show Pause Reset Input.
b) Once the condition that caused the Show Pause has been re-
moved, the operator can press the Show Continue button.
U) DMX-512 Receive LED (v3.0+ Only)
(One red LED, Located on back of Kp-300)
To support the DMX-512 input, the v3.0+ Kp-300 adds an LED that
flashes on each update via the DMX-512.
The Kp-300 requires DMX-512 that includes GilderChecksums.
If receiving DMX-512 without valid checksums, the DMX-512 Receive
LED on the back of the Kp-300 will not flash and only the Show Start Button
LEDs will follow the incoming the DMX-512. The signals like the Show Start
Button Enable Inputs, blocking valve enable, and automatic HPU start/stop
will not work if the GilderChecksums are invalid.
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Kp-300 Manual / September 4, 2012 4:29 PM / page 21 of 75
5
In some applications, you may want to call up a different show using this input, instead of pausing the current show.