If shows must be run in a certain order, you can program this into the mo-
tion profile stored on the Smart Brick System. An example of this would be a
motion base that has separate entrance and exit doors. The main shows all
lead into a show that leaves the exit doors opened
6
. The only show that is
enabled for the operator is a short show that closes the exit doors (and
maybe turns off the cabin lights) so that the system is ready to be parked or
loaded with the next group of riders. The operator would start this show once
he confirmed that the cabin was clear. At the end of this show another show
is enabled that opens the entrance door (and turns on the cabin lights). The
operator would call this up when it is time to load the next batch of riders. At
the end of this short show, the main shows are enabled for the operators.
One of these would be started once all the riders were safely seated (and
the belts logged, if needed). All of these short shows can have accompany-
ing audio and/or video if it has been programmed on whatever audio/image
source is being used.
The Br-ANA Analog Output Smart Brick can be configured to do an Ease
In whenever the Smart Brick System jumps from one show to another. This
makes it safe for you to configure the system to jump between shows as de-
scribed above.
D) HPU Start Button
This Button is used to set the latch on the Kp-300 that turns on the HPU
Run Output. This is an optional feature. If you donʼt want the HPU to be
started and stopped remotely, just donʼt use this button.
The HPU Start Button parallels the Remote HPU Start Input from the
Smart Brick System. If the HPU is being forced off by a HPU Stop Buss error
or a Remote HPU Stop Input from the Smart Brick System, the HPU Start
Button can not override them.
Any of the ʻstopʼ inputs take precedence over any of the ʻstartʼ inputs. You
can use an active Remote HPU Stop Input in the motion profile stored on the
Smart Brick System to keep the operator or Remote HPU Start Input from
starting the HPU.