DipSwitch settings on the Kp-300 (v3.0+)
(EIGHT POSITION DIPSWITCH)
The DipSwitch is used to select several options on the v3.0+ Kp-300s:
A) DipSwitch #1: HPU Stopped LED Internal/External
OFF# = HPU Stopped LED controlled by an external switch
ON# = HPU Stopped LED controlled internally
If your HPU has a switch that closes when the HPU is not running, you
should wire this switch to the HPU Stopped Input pins #1 and #14 on the J2
connector. If your HPU doesnʼt have a ʻstoppedʼ switch output, or you donʼt
even have a HPU in your application, turning this switch on will light the
ʻHPU stoppedʼ LED when the Kp-300 thinks the HPU shouldnʼt be running.
Unlike the HPU Running Input, the HPU Stopped Input is not used for any
other purpose than lighting this LED.
B) DipSwitch #2: HPU Running LED Internal/External
OFF# = HPU Running LED controlled by an external switch
ON# = HPU Running LED controlled internally
If your HPU has a switch that closes when the HPU is not running, you
should wire this switch to the HPU Running Input pins #2 and #15 on the J2
connector. If your HPU doesnʼt have a ʻstoppedʼ switch output, or you donʼt
even have a HPU in your application, turning this switch on will light the
ʻHPU Runningʼ LED when the Kp-300 thinks the HPU shouldnʼt be running.
C) DipSwitch #3: E-Stop Disables Show Starts
OFF# = Does nothing
ON# = E-Stop Buss disables new show starts
When on, this DipSwitch will keep any shows from being started When
the E-Stop buss is active (the E-Stop Buss LED is lit) using the ʻShow Startʼ
buttons, even if the ʻShow Startʼ Enables are active.
D) DipSwitch #4: HPU-Stop Disables Show Starts
OFF# = Does nothing
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485