Owner manual

a) The motion base is programmed with all axis at the parked posi-
tions. This can be seen in the upper, analog data pane. All the ana-
log channels are down along the bottom ʻ0%ʼ line in the E-Stop and
Load/Unload Shows.
b) Disable the Blocking Valve Output to the Kp-300. This will park a
hydraulic Motion base (the hardware on the Kp-300 will have actu-
ally turned off the output before this). The ʻBlocking Valveʼ output is
ʻoffʼ through all four seconds of this show.
c) Turn on the ʻE-Stop Show Runningʼ Output to the Kp-300. If you
donʼt do this, you wonʼt be able to restart the HPU to get yourself
out of the E-Stop event. The ʻE-Stop Showʼ output is ʻonʼ through
the entire show.
d) Turn on any of the Bypass Outputs that are needed to recover from
the E-Stop event. In this application, the ʻBypass 1ʼ is used during
the E-Stop and Load/Unload shows to keep the doors being
opened and people walking in and out from triggering additional E-
Stops.
e) Flash the Show Start Button LED(s) for whatever show(s) you want
the operator to be able to call up next. This is so the operator knows
which show options are available. We typically program them in a
chase pattern during the E-Stop and Load/Unload shows, lighting
only the valid show selections. The eight ʻShow Pilotʼ outputs are
shown doing a simple circular chase pattern.
f) Whenever a Show Start Button LED is programed to indicate that a
Show Start Buttons is valid, it is also necessary to actually enable
the corresponding Show Start Button Enable Input from the Smart
Brick System to make the Show Start Buttons active. If this is not
done, then the Show Start Buttons will remain inactive. All eight
ʻShow Enablesʼ are ʻonʼ through the show, so all eight Show Start
Buttons are enabled.
g) The ʻShow Pause Resetʼ is ʻonʼ through the show to reset any po-
tential ʻpausesʼ.
h) The ʻBypass 2ʼ, ʻHPU Startʼ, ʻHPU Stopʼ and ʻCycle Counterʼ are not
used during the E-Stop show.
i) Open any cabin doors as needed to allow the passengers to be
evacuated.
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Kp-300 Manual / September 4, 2012 4:29 PM / page 39 of 75