Owner manual

Program a Remote HPU Start Input into the show data. When
the HPU is started as part of the motion profile, there will usually
be a time just after it is started where any HPU pressure sensors
inputs will need to be bypassed. In this case, you can see ʻBy-
pass 2ʼ being used for this at the start of the show. The Bypass
Buss needs to be active for the time it takes for the HPU to build
up pressure. If the pressure sensor doesnʼt come up during the
time allotted, the Kp-300 will automatically trigger an error condi-
tion.
e) (optional)If you are using the Remote HPU Stop Input features: If
the HPU is to be turned off at the end of the show, then the same
Bypass Buss which is being used for turning on the HPU will
need to be programmed active along with a pulse on the Remote
HPU Stop Input. This allows the HPU to be stopped without trig-
gering an error condition. If configured to trigger an E-Stop, the
Bypass Buss may also need to be programmed active during the
E-Stop and Load/Unload shows so that the HPUʼs low pressure
wonʼt trigger an error during these shows when the HPU is off.
f) Turn off the Show Start Button LEDs. We typically program them
in a chase pattern during the E-Stop and Load/Unload shows,
lighting only the valid show selections. Once a show has started,
we typically program all but the selected Show Start Button
LEDs off, and flash the selected show LED a few times before
turning it on through the rest of the show. If any other show se-
lection is valid while another show is running, we then flash it
discretely throughout the show that is running. In this case, no
other shows can be started during this ʻMainʼ show.
# Whenever a Show Start Button LED is programed to indicate
that a show select Show Start Buttons is valid, it is also neces-
sary to actually enable and/or disable the corresponding Show
Start Button Enable Input.
g) Enable/Disable the Show Start Button Enable Input for whatever
show(s) you want the operator to be able to call up next. Typi-
cally there arenʼt any during the Main shows. If there is one, then
it is probably a show that has been written to ʻparkʼ the motion
base without having to E-Stop the system.
h) Just before the ride comes to an end, pulse the ʻCycle Counterʼ
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485