motion base applications, the power is removed from the blocking
valves during the Load/Unload times so that there is no possibility of
the motion base moving while riders are walking in and out.
This input is used for motion profile stored in the Smart Brick Sys-
tem to request that the blocking valve attached to the motion base be
turned ʻonʼ to allow the motion base to move. Unless the Kp-300 is re-
ceiving an active HPU Running Input and the Kp-300 is not in an E-
Stop condition, the Blocking Valve Input from the Smart Brick System
will not be passed through to the Blocking Valve Output.
5. Bypass Buss #1 Input to Kp-300
6. Bypass Buss #2 Input to Kp-300
These inputs are used by the motion control profile to bypass some
or all of the Safety inputs which have been configured to create an E-
Stop or Show Pause. Typical examples of the use of the bypass buss
are:
a) HPU Startup/Shutdown: If the HPU is started and stopped as
part of the motion profile, there will usually be a time just after
it is started and a time after it is stopped where any HPU
pressure sensors inputs will need to be bypassed. Do this by
programming the Bypass Buss you are using and Remote
HPU Start Input to be active at the beginning of the show. The
Bypass Buss needs to be active for the time it takes for the
HPU to build up pressure. If the pressure doesnʼt come up
during the time allotted, the Kp-300 will automatically trigger
an error condition (either E-Stop or Show Pause, as config-
ured).
# If the HPU is to be turned off at the end of the show, then
the Bypass Buss which is being used would be programmed
active along with a pulse on the Remote HPU Stop Input. This
allows the HPU to be stopped without triggering an error con-
dition. If configured to trigger an E-Stop, the Bypass Buss
may also need to be programmed active during the E-Stop
and Load/Unload shows so that the HPUʼs low pressure wonʼt
trigger an error during these shows when the HPU is off.
b) Door Sensors: If the door or floor mat sensors inputs are set
to trigger an E-Stop, they will need to be bypassed during the
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485