Owner manual

4) Remote HPU Start Input to Kp-300
This input is used by the motion control profile on the Smart Brick System to
commands the HPU to start. This is an optional feature. If you donʼt want the HPU
to be started and stopped automatically, just donʼt use it.
The Remote HPH Start Input parallels the HPU Start button on the front of the
Kp-300. If the HPU is being forced off by a HPU Stop Buss error, the HPU Start
button or Remote HPU Start Input cannot override the error.
Any of the ʻstopʼ inputs take precedence over any of the ʻstartʼ inputs. You can
use an active Remote HPU Stop Input in the motion profile stored on the Smart
Brick System to keep the operator or Remote HPU Start Input from starting the
HPU.
5) Remote HPU Stop Input to Kp-300
This input is used by the motion control profile on the Smart Brick System to
commands the HPU to stop. This is an optional feature. If you donʼt want the HPU
to be started and stopped automatically, just donʼt use it.
The Remote HPH Start Input parallels the HPU Start button on the front of the
Kp-300. If the HPU is being forced off by a HPU Stop Buss error, the HPU Start
button or Remote HPU Start Input cannot override the error.
Any of the ʻstopʼ inputs take precedence over any of the ʻstartʼ inputs. You can
use an active Remote HPU Stop Input in the motion profile stored on the Smart
Brick System to keep the operator or Remote HPU Start Input from starting the
HPU.
6) Show Pause Reset Input to Kp-300
This input is used by the motion control profile on the Smart Brick System to
reset or disable the Kp-300 Show Pause functions. This is normally programmed
active only during the E-Stop and Load/Unload shows.
Seat belts can be logged at any time that the Show Pause Reset Input from the
Smart Brick System is active. When this input is active, the safety inputs can be
logged by either pressing the Log Belts Button or activating the Remote Log Belts
Input by pressing the Remote Log Belts Button(s) attached to it.
If you want to automatically log belts from the motion profile, just set the Re-
mote Log Belts Input for Internal Power and attach the two wires for this input to-
gether so it is always active. Whenever the Show Pause Reset Input is pro-
grammed active, the inputs that are set to be logged will automatically be logged.
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Kp-300 Manual / September 4, 2012 4:29 PM / page 60 of 75