Owner manual

Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Kp-300 Manual / September 4, 2012 4:29 PM / page 8 of 75
KP-300 Expansion • Gilderfluke & Company, Burbank, California
Relay Outputs
1/4 J6 Outputs
Inputs
J6 Inputs
3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7
2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7
1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7
2019181716151413121110987654321
654321 6543210 7
Kp-300 Typical Block Diagram for a Hydraulic Motion Base
HPU
Door, Ramp,
Seat Belt and
other 'Safety'
Switches
HPU error signals
(Oil low, overtemp,
lter dirty, etc.)
HPU Run Output
HPU Run/Stop
Status Signals
Kp-300
Kp-300 Expansion(s)
(if needed)
Pb-DMX with
3.5 Amp
Relays
Audio/Video
Playback
Light Dimmers
RGB LED
Lamp Fixtures
Br-ANA or
DAC-Quad
EFB-Quad(s)
or PID-Quad(s)
Valves, Cylinders
and position
sensors
Moving Head
Light Fixtures
Smog
Machines
Moving head
Light Fixtures
Br-MiniBrick8
Strobe Lights
Fans
other DMX-512
compatible
equipment
Br-Brain4
(typically)
Network
(DMX-512)
Four or
sixteen
0-10 VDC
commands