Owner's manual

tive show in line
b) Show 7 requests show number 1 at it’s end
c) Show 10 through 16 each request the next consec-
utive show in line
d) Show 17 has a ‘00’ entered for the next show at it’s
end
Once started, the shows 1 through 7 will loop for ever
A request comes in for show 10 while playing show 3
Shows 10 through 17 are played
At the end of show 17, the next show played will be
show number 4
An exception to the rule above is made for shows
240 through 255 (0F0h through 0FFh). These shows are
to be used for ‘background’ shows. It is show #255 that is
called up when both the IMMEDIATE CHAIN FLAG and
DELAY FLAGS are set for a single show. When any of
these shows are playing, and another show is request-
ed, show numbers from 240 through 255 won’t be
saved as the ‘return’ shows.
“g” Frame Rate:
This command is used to set the Frame Rate for this
show. This is the number of times each second which the
Smart Brick System will update all of the outputs with new
data.
Smpte: Valid frame rates for Smpte synchronized
shows are 12, 15, 24, 25, and 30 frames per sec-
ond.
LaserDisk: Valid frame rates for LaserDisk (or DVD)
synchronized shows are 15, 25, and 30 frames per
second.
GILDERFLUKE & CO .205 SOUTH FLOWER STREET BURBANK , CALIFORNIA 91502 818/840-9484 800/776-5972 FAX 818/840-9485