Operating Instructions Room Temperature Controller 230/10 (4) A~ with NC contact and On/Off button 0392 ..
Contents Operating instructions Room temperature controller 230/10 (4) A~ with NC contact and On/Off switch 3
Installation of the room temperature controller Area of application The room temperature controller is used to control the temperature in closed rooms, such as apartments, schools, lecture halls, workshops etc. Installation site • Install the room temperature controller on an interior wall and, if possible, directly across from the heat source. • Comply with the recommended installation height of approx. 1.5 m above the floor. • The permissible relative humidity may not exceed the max. of 95 %.
• Ensure that the normal convective air of the room can reach the room temperature controller unimpeded. For this reason, the controller is not to be mounted within shelf walls or behind curtains or similar coverings. • Heat from other sources negatively influences controller precision. For this reason, avoid direct sunlight and objects which emit heat (televisions, heaters, lamps, chimney, heating pipes etc.).
Installation site 6
Installation Attention Installation and mounting of electrical devices may only be carried out by a qualified electrician. If the mounting and installation instructions are not complied with, a danger of fire and other dangers can arise. The room temperature controller is mounted in a 58-mm flush-mounted box in accordance with DIN 49 073. To install the room temperature controller, proceed as follows: 1. Remove housing cover: Pull off setting knob. Loosen cover screw. Pull off cover.
2. Electrical connection in accordance with wiring schematic (see Page 10). 3. Mount device into flush-mounted box with screws. Attention: Always mount support ring on wallpaper. The support ring may not be wallpapered over when renovating. 4. Set housing cover with cover frame in place. Engage housing cover at the top left in the housing basis and tighten screw. Attach setting knob.
Electrical connection. Connect all cables in accordance with the wiring schematic (see Page 10). Ensure that the neutral conductor is connected to terminal N. If this is not done, great temperature fluctuations will result, as the room temperature controller cannot work properly. An earthed connection is not required, as the device is double insulated.
Wiring schematic 10
Key to wiring diagram L = external conductor N = neutral conductor = connection for clock signal for temperature reduction = heating load connection RF = resistance for heat return TA = resistance for night-time heating reduction of room temperature = LED (LED on: controller active) 11
Setting the temperature limits Two setting rings are found in the setting knob. You can set the temperature limits as desired with them. The temperature controller is set to the maximum setting range of 5 °C to 30 °C at the factory. Setting procedure To set the temperature limits (in this example: min. 8 °C, max. 23 °C): 1. Turn the setting knob to the centre of the desired setting range. Example: The centre between 8 °C und 23 °C is 15 °C. 2. Pull off setting knob.
3. To set the red setting ring to the upper temperature limit (23 °C here): Insert a pointy object (e.g. pen) into one of the holes of the red ring. Rotate the red ring anticlockwise to 23 °C. The outer numbers of the scale apply here.
4. To set the blue setting ring to the lower temperature limit (8 °C here): Insert a pointy object (e.g. pen) into the hole of the blue ring. Rotate the blue ring clockwise to 8 °C. The inner numbers of the scale apply here. 5. Attach setting knob. Here, the indicator must be located approximately at the centre of the new setting range (see Item 1). Example: approx. 15 °C.
Temperature adjustment When commissioning the room temperature controller, note that the thermo-bimetal requires a certain amount of time to adjust to the room temperature. This is why the switching point will deviate from the room temperature immediately after mounting or after night-time heating reduction switches off. The switching point is not precise until after one to two hours of operation.
Temperature setting scale The scale for the temperature setting is found on the cover of the room temperature controller and is used for visual orientation when setting the temperature (from min. 5 °C to max. 30 °C). = approx. 5 °C 2 = approx. 10 °C 3 = approx. 15 °C = approx. 20 °C 5 = approx. 25 °C 6 = approx.
Technical data Temperature range: Rated voltage: Rated current: Contact rating: Switching temperature differential: Night-time heating reductions: Conductor cross-section: 5 °C to 30 °C 230 V AC 10 (4) A approx. 2200 W approx. 0.5 K approx. 4 K 1 to 2.5 mm solid conductor.
Warranty The warranty is provided in accordance with statutory requirements via the specialist trade. Please submit or send faulty devices postage paid together with an error description to your responsible salesperson (specialist trade/installation company/electrical specialist trade). They will forward the devices to the Gira Service Center.