Mounting Instructions and Commissioning for Qualified Electrician 41 05 06 08/05 Radio room temperature sensor with clock 1186 ..
Table of contents On these instructions On these instructions ............................................................................. 3 The following symbols and marks are used in these instructions: Method of functioning ........................................................................... 3 1. Action instructions are numbered consecutively. Installation .............................................................................................
Installation Installation and safety instructions Attention Installation and mounting of electrical devices may only be carried out by a qualified electrician. The radio room temperature sensor is conceived for flush-type mounting. It consists of two units: • The flush-mounted insert which contains the power electronics, the radio transmitter and the connections (for flush-mounting box) • The controller top unit with the operating elements which is attached to the flush-mounted unit.
Teaching-in radio connection – LErn menu item Start-up (basic setting) To assign radio motor valve drive(s) or a radio controller to the radio room temperature sensor, proceed as follows: 1. In normal display press the P button at least 5 seconds in order to access the program menu. 2. Press the + or - button in order return to the LErn menu item.
To improve clarity the respective character listed above is displayed in the top left of the display. The corresponding value is displayed on the right in the four large numerals. Normal display (n) This parameter is used to select the normal display of the radio room temperature sensor. This information is always displayed on the display whenever no menu has been selected and no holiday settings are active. 1. The + and - buttons can be used to change to one of the operating modes listed below. 2.
Heating optimisation (E) Operating mode (b) This parameter allows individual selection of the function for the radio room temperature sensor. This defines the frequency of the radio transmission (convection heater, floor heating, radio controller). 1. The + and - buttons can be used to change to one of the operating modes listed below. 2. S activates it.
Gradient for heating optimisation (r) Accuracy (U) The current gradient which is used to calculate the derivative action time can be checked under this menu item. The time required to heat the room by one Kelvin (1K) is displayed here in minutes. Here a correction value is entered at the factory, which ensures the greatest possible precision of the clock function. If the heat optimisation is activated, this gradient is always recalculated during a transition from a lowering phase to a comfort phase.
Technical data Temperature ranges: Information on radio operation + 18 to + 30 °C (comfort temperature) + 10 to + 22 °C (comfort and lowering temperature) + 5 to + 15 °C (frost protection temperature) + 10 to + 30 °C (individual temperature) - 3 to + 3 K (setpoint offset during operation with radio controller) Radio transmission occurs on a non-exclusive transmission path, and interference cannot be excluded for this reason. The radio transmission is thus not suitable for security purposes, e.g.
Acceptance of guarantee We accept the guarantee in accordance with the corresponding legal provisions. Please return the unit postage paid to our central service department giving a brief description of the fault. Gira Giersiepen GmbH & Co. KG Service Center Dahlienstraße 12 42477 Radevormwald, Germany The CE sign is a free-trade mark intended solely for state authorities and does not contain any assurance of properties. Gira Giersiepen GmbH & Co. KG Postfach 1220 42461 Radevormwald, Germany Tel.
Operating Instructions Radio room temperature sensor with clock 1186 ..
Table of contents On these instructions On these instructions ............................................................................. 3 The following symbols and marks are used in these instructions: How the radio room temperature sensor functions ................................ 3 1. Action instructions are numbered consecutively. Normal view in the display .................................................................... 4 ✓ Results of actions are identified by this check mark.
Normal view in the display The individual displays and buttons 1 The current weekday is displayed here. 2 Symbol for the "Time program" operating mode. 3 Symbol for the "Comfort temperature" operating mode. 4 Symbol for the "Lowering temperature" operating mode. 5 Symbol for the "Anti-freeze temperature" operating mode. 6 The respective current operating mode is indicated here by means of triangles. 7 The ranges set for the comfort temperature in the time program are displayed here.
Starting up the radio room temperature sensor Prolonging the heating phase (party function) When the radio room temperature sensor is switched on for the first time, as well as after long deactivation periods, e.g. after a power failure, the radio room temperature sensor jumps automatically to the time input – the current data must be entered here. (You can edit these data later --> for details, please refer to „Setting the date and time – Uhr (Clock) menu item" on Page 7).
Changing over to the lowering temperature (economy button) Setting the individual temperature You can change over to the lowering temperature for brief or long-term periods of absence by means of the economy button. Switching for brief periods to the lowering temperature 1. Press the button for less than 5 seconds. ✓ The radio room temperature sensor switches over to the lowering temperature. The Lowering temperature mode is displayed.
Settings in the program menu Deactivating the individual temperature You can change the following settings in the program menu: You can deactivate the individual temperature at any time: • Date and time (Uhr (Clock) menu item) 1. Press the P button in order to deactivate the individual temperature. • Temperature steps (tEmP menu item)* ✓ The radio room temperature sensor returns to the normal time program.
To set the date and time: Modifying the temperature steps – tEMP menu item 1. Go in the program menu to the Uhr (Clock) menu item (see above). Function deactivated ✓ The hour display flashes. 2. Press the + or - button until the desired hour has been set. i Time format You can have the time displayed in international 24 hour format or in the American format (AM/PM). Details are provided on Page 5. During operation with the radio controller, this function is deactivated.
To change the temperature steps: 1. Go in the program menu to the tEMP menu item (see Page 7). ✓ The temperature setting of the comfort temperature is displayed flashing. In addition the operating mode is displayed at the right-hand display margin. 2. Press the + or - button in order to set the desired temperature. 3. Confirm with the S button. ✓ The display changes automatically to the next temperature step, the lowering temperature. 4.
Modifying the switching time Deleting the switching time 1. Go in the program menu to the ProG menu item (see Page 7). 1. Go in the program menu to the ProG menu item (see Page 7). 2. Press the + or - button in order to access the desired switching time. 2. Press the + or - button in order to access the desired switching time. 3. Press the S button for the switching time to be changed. 3. Press the + and - buttons for longer than 5 seconds.
Inserting a new switching time Aborting the settings at the time program 1. Go in the program menu to the ProG menu item (see Page 7). You can abort the modifications at the time program if no switching time is opened for processing. 2. Press the + or - button in order to access the empty switching time. 3. Confirm with the S button. You can now carry out all the settings for a new switching time: ✓ The new switching time is opened for editing, the hour display flashes. 4.
Setting the holiday program – UrLb menu item Function deactivated During operation with the radio controller, this function is deactivated. The holiday programs are managed centrally by the radio controller. A holiday program is available in the UrLb menu item. You set the starting date and end date of your absence here. During this period the system regulates to a constant selectable temperature step.
Activating/deactivating the anti-freeze function – FrSt menu item Function deactivated During operation with the radio controller, this function is deactivated. The anti-freeze function is managed centrally by the radio controller. You can only permanently activate the anti-freeze function here. i Anti-freeze temperature The anti-freeze function can only be set in operation between +5 °C and +15 °C. 1. Go in the program menu to the FrSt menu item (see Page 7).
Teaching-in radio connection – LErn menu item To assign radio motor valve drive(s) or a radio controller to the radio room temperature sensor, proceed as follows: 1. Go in the program menu to the LErn menu item (see Page 7). 2. Start the programming mode on all devices to the taught in. 3. Press the S button on the radio room temperature sensor to start the teach-in process. ✓ During the teach-in process the LErn display flashes. ✓ After approx.