Installation and Operating Instructions Door Station Stainless 2501 20, 2502 20, 2503 2504 20, 2506 20, 2508 2509 20, 2510 20, 2512 Steel 20 20 20
Table of contents Device description ......................................................................................................5 Installing panel box .....................................................................................................6 Installing front panel ...................................................................................................8 Start-up ..................................................................................................................
Device description The Door Station Stainless Steel is a pre-assembled, vandalism-protected door station for the Gira door communication system. The front plate of high-quality V2A stainless steel with a thickness of 3 mm is especially robust. The call buttons are also made of durable stainless steel. The illuminated inscription labels are covered by a fully secured and flameproof glass plate. The inscription labels can be opened via a covered mechanism and can then removed from the front.
Installing panel box Attention Installation and mounting of electrical devices may only be carried out by a qualified electrician. 1. Select a suitable installation site and chisel an opening in the wall. 2. If necessary, mount the included wall anchor. Note the following information when mounting the panel box: • Ensure installation position is correct. (note the "TOP" labelling). • The panel box must be installed level.
4. Mount the included plaster protection. 5. Plaster the wall. 6. Carefully remove the plaster and take out the plaster protection.
Installing front panel 1. Insert the locking plate flushly into the panel box. i Insert locking plate evenly The locking plate must not be twisted while being inserted into the panel box and must not be under tension. Push the locking plate inwards until the plastic brackets touch the wall. 2. Fasten the locking plate with the 4 Allen bolts and locking washers included. In order to guarantee a secure fastening of the front panel later, the Allen bolts must be firmly tightened. 3.
5. Pull the front panel from the mounting retainers (1.) and fold these in (2.). 2. 1. 6. Position the (lower) fastening bolt(s) of the front panel to "Close". Open Close 7. Mount the front panel onto the guide bolts and press it on until the upper and lower fastening bolts engage. Starting up Once all of the devices (door and home stations, control device etc.) have been installed, the door communication system can be started up.
Replacing inscription label Inscription labels For labelling the Gira Door Station Stainless Steel, use only Gira inscription labels. The transparent plastic labels are non-fading, weather-resistant and wrinkle-free. With the included release code, inscription labels for the first labelling are available free at www.marking.gira.com cli ck 1. Unlock the call button with the enclosed plastic key: twist the plastic key anti-clockwise until it engages. 120° 2.
5. Position the inscription label underneath the clips of the inscription label carrier. 6. Slide in the inscription label carrier again. At the same time, position the inscription label with your finger. click ustermann click 7. Release the call button: To do this, press in the plastic key slightly and turn it clockwise until the call button is released from the lower position. 8. Lock the call button: To do this, turn the plastic key clockwise again until it engages. ustermann 9.
Opening Door Station Stainless Steel The included opening tool is required for opening the Door Station Stainless Steel. 1. Turn the (lower) fastening bolt(s) with the opening tool to "Open". Single-column door stations have one lower fastening bolt, double-column door stations have two lower fastening bolts. The position of the fastening bolts is shown via small recesses on the lower side of the front panel.
Operation Volume setting The volume can be set separately at each door station. The volume setting must be made by two people. 1. Press the "Systemprogr." button on the control device for 3 sec. to start programming mode. 1x M. Meier 2. Briefly press a previously assigned call button at the door station. 3. The second person accepts the door call at the home station (via receiver or speech button) and starts speaking. 1x 4. Briefly press the call button again at the door station. M.
Technical data Connections: 2 2 2 1 2 screw terminals for 2-wire bus screw terminals for additional supply system bus connector strips (6-pole) video connector strip (2-pole) sabotage contact screw terminals Protection type: IP 44 Operating temperature: -25 °C to +70 °C Dimensions (W x H x D): 1-gang, 2-gang, 3-gang: 140 x 198 x 40 mm (panel box) 160 x 218 x 3 mm (front panel) 4-gang, 6-gang: 140 x 265 x 40 mm (panel box) 160 x 285 x 3 mm (front panel) 8-gang, 9-gang: 140 x 332 x 40 mm (panel bo
Postfach 1220 42461 Radevormwald Deutschland Tel +49 (0) 21 95 / 602 - 0 Fax +49 (0) 21 95 / 602 - 191 www.gira.de info@gira.de 10 41 09 22 20/11 Gira Giersiepen GmbH & Co.