© GKD Technik Ltd 2021 Sensor Zone User Manual (WiFi) M4000001 Version 08/21
4
3 In-Cab Operation
It is recommended a copy of this page and the relevant display unit page
are placed within the vehicle cab.
3.1 System Start Procedure
All machine operators are required to carry a tag.
1. The machine operator must be carrying a tag
2. Ensure no other tags are in the exclusion zone
3. Start the machine and the PWS system will automatically initialise
4. When the alarm/Beep sounds (approximately 3 seconds after startup) press
the Acknowledge button.
5. If the Acknowledge button is not pressed within 15 seconds of the system
start-up Beep then switch off and start the procedure again.
3.2 Troubleshooting
If the system does not initialise correctly the internal and external alarms will
continuously sound indicating an unauthorised operating state.
If the system does not enter the operating state when the Acknowledge button is
pressed then check the following
1. That there are no additional tags in the exclusion zone (these maybe on
pedestrians, drivers in other machines nearby, or a tag left in the cab by a
previous operator.
2. That your tag is functioning. Test your tag at a Tag Test station.
When the system is in operation, tags that enter the exclusion zone are
automatically detected.