User's Manual
© GKD Technik Ltd 2021 Sensor Zone User Manual (WiFi) M4000001 Version 08/21
6
5 SystemsttedwithaPushButtonDisplay
Alarm LED
Acknowledege
5.1 If a single tag enters
the exclusion zone
The push button display will
ash the Alarm LED and Beep
once every second.
If an external alarm Sounder/
Beacon is connected to the
Base Station both the alarm will
sound and the beacon will ash.
This will repeat until the
operator presses the
“Acknowledge” button.
Once acknowledged the alarms will silence and the beacon will stop ashing.
5.2 If more than one tag enters the exclusion zone
The AlarmLED and Beep will indicate the number of tags that have
entered the eld:
2 Tags detected = 2 ashes and 2 Beeps.
4 Tags detected = 4 ashes and 4 beeps.
10 Tags detected = 10 ashes and 10 beeps.
To acknowledge more than one tag, the “Acknowledge” button must be
pressed for each tag. A one-second pause is required between each press of
the “Acknowledge” button.
5.3 External Sounder/Beacon
If the GKD SensorZone Sounder Beacon is selected the
following operating modes will apply
System on = Beacon will ash slowly.
Zone Incursion = Beacon ashes and alarm sounds.
Incursion acknowledged = Beacon ashes slowly
and no alarm sounding.