5 SystemsttedwithaPushButtonDisplay
Alarm LED
Acknowledege
5.1 If a single tag enters
the exclusion zone
The push button display will
ash the Alarm LED and Beep
once every second.
If an external alarm Sounder/
Beacon is connected to the
Base Station both the alarm will
sound and the beacon will ash.
This will repeat until the
operator presses the
“Acknowledge” button.
Once acknowledged the alarms will silence and the beacon will stop ashing.
5.2 If more than one tag enters the exclusion zone
The AlarmLED and Beep will indicate the number of tags that have
entered the eld:
2 Tags detected = 2 ashes and 2 Beeps.
4 Tags detected = 4 ashes and 4 beeps.
10 Tags detected = 10 ashes and 10 beeps.
To acknowledge more than one tag, the “Acknowledge” button must be
pressed for each tag. A one-second pause is required between each press of
the “Acknowledge” button.
5.3 External Sounder/Beacon
If the GKD SensorZone Sounder Beacon is selected the
following operating modes will apply
System on = Beacon will ash slowly.
Zone Incursion = Beacon ashes and alarm sounds.
Incursion acknowledged = Beacon ashes slowly