Indicator light on the
control valve is flashing.
Six months usage has occurred. This is the
maximum life of the filter canisters.
If double flash, replace filters.
If single fading flash, replace
filters and batteries.
Troubleshooting (continued)
Problem Possible Cause Solution
Indicator light on the
control valve is not
blinking
Normal operation. Does not blink until 6 months
of operation has passed.
Normally the light is not on. The
light blinks every 20 seconds
to indicate a filter change is
needed. This occurs about
every 6 months.
Battery may need to be replaced. Replace battery and press reset
button for 5 seconds. Indicator
will light to indicate proper
installation and operation. Timer
is reset for 6 months.
Indicator light on the
control valve is not
working when new
battery is installed.
Battery may have been installed incorrectly
or wire not connected.
Observe battery orientation
markings on the holder.
Ensure wire is connected from
control valve to timer box.
Press reset button for 5 seconds
to reset timer, indicator will light
and timer is reset for 6 months.
Chlorine taste and odor
in the product water.
The filter canisters are no longer reducing
chlorine taste and odor from the water
supply.
Replace the filter canisters.
Water dispenses very
slowly.
The filters have been installed for too long. A six-month change-out period
is recommended. Replace both
filter canisters.
The filter canisters have become clogged. High sediment levels can cause
premature clogging. Replace
both filter canisters.
Filter not installed fully. Ensure filter is fully installed,
label should be centered and
facing forward.
Fittings are leaking. Tubing may not be installed properly. Fully follow the installation
instructions and be sure the
tubing is free of nicks, burrs,
etc., and is installed to the
proper depth.
No water dispensing from
system.
Filter canisters not fully installed. Fully follow the filter
replacement instructions.
Water has air bubbles and
is cloudy.
Air in system after installation. Will go away after water runs
for a while.