Installation Guide
10
Installation (continued)
9
Installing the filtration system
□ Before installation, select the location for the ltration manifold (J). The screws should be placed a
minimum of 15 in. above the bottom of the oor where the ltration system is to be mounted. Any
distance lower may result in the lter set (K) interfering with the oor when removing the lters for
maintenance.
□ Use the ltration manifold (J) as a template to mark the screw hole locations where the screws are to be
installed.
Installing into drywall: Drill two 1/4 in. holes and insert the anchors (M) and screws (L).
Installing into wood: Drill two 1/8 in. holes and insert the screws (L). Do not use anchors (M).
Install screws into the wall, leaving 3/16 in. to 3/8 in. clearance between the head of the screw and wall.
□ Hang the ltration manifold (J) on screws (L) until the ltration manifold (J) is held rmly.
NOTE: The base of the control valve will ash red when its time to change lters and batteries. When it double ashes, 6 months have
passed and its time to replace the lters. When it ashes a single fading ash, 1 year has passed and it is time to replace the lters and
the timer batteries, then press reset button for 5 seconds to reset timer.
J
M
L
L
L
3/16 in. to 3/8 in.
Wall
15 in. Min.
1
2
2
1