Specification

FRP Wall & Ceiling Liner Panels
097700 - 5
8. Coefficient of Linear Thermal Expansion, ASTM D 696: 2.39 x 10
-5
inches/inch/degree F.
9. Barcol Hardness, ASTM D 2583: 35 average.
10. Specific Gravity, ASTM D 792: 1.5743.
11. Abrasion Resistance, Tabor Weight Loss: 0.391 percent weight loss.
12. Flash Ignition Temperature, ASTM D 1929: 400 degrees C.
13. Self Ignition Temperature, ASTM D 1929: 430 degrees C.
14. Surface Burning Characteristics, ASTM E 84:
a. Flame Spread Index: 25.
b. Smoke Developed Index: Less than 450.
D. Physical Properties, Glasliner FRP Ceiling Liner Panels:
1. Sag, ASTM C 367, 23-3/4 Inches by 47-3/4 Inches Panel: 0.193-inch to 0.25-inch sag.
2. Surface Burning Characteristics, ASTM E 84:
a. Flame Spread Index: 200.
b. Smoke Developed Index: 450.
2.3 ACCESSORIES
A. Moldings: PVC, same manufacturer and color as liner panels.
1. Dividers.
2. Outside corners.
3. Inside corners.
4. End caps.
5. Angles.
B. Fasteners: Nylon rivets, 1-piece, non-corroding, same manufacturer and color as liner panels.
C. Silicone Sealant: As specified in Section 07920 (07 92 00).
D. Adhesive: Water-based or solvent-based adhesive, compatible with Glasliner FRP liner panels.
PART 3 EXECUTION
3.1 EXAMINATION
A. Examine areas to receive liner panels. Notify Architect of conditions that would adversely affect
installation or subsequent use. Do not proceed with installation until unsatisfactory conditions
are corrected.
3.2 PREPARATION
A. Ensure solid wall surfaces to receive liner panels are plumb, clean, flat, smooth, and dry.
B. Precondition liner panels before installation in accordance with manufacturer's instructions.
3.3 INSTALLATION
A. Install liner panels in accordance with manufacturer's instructions.
B. Install liner panels over plumb, clean, flat, smooth, dry, solid wall surfaces.
C. Install liner panels plumb, level, square, and in proper alignment.