Installation

Determining the Rough Opening “RO” Dimension
Framing in new construction should follow these dimension. Standard 2x4 studs and 1/2” sheetrock are shown
in the illustrations. For 6” deep models 2x6 studs are required or a semi-recessed application is necessary.
Model Number Rough Opening Single Cabinet Rough Opening Two (2) cabinets Rough Opening Three (3) cabinets
Width Height Width Height Width Height
GC1624 14 3/8” 23 3/8” 29 3/8” 23 3/8” 44 3/8” 23 3/8
GC1630 14 3/8” 29 3/8” 29 3/8” 29 3/8” 44 3/8” 29 3/8”
GC1636 14 3/8” 35 3/8” 29 3/8” 35 3/8” 44 3/8” 35 3/8”
GC2030 18 3/8” 29 3/8” 37 3/8” 29 3/8” 56 3/8” 29 3/8”
GC2036 18 3/8” 35 3/8” 37 3/8” 35 3/8” 56 3/8” 35 3/8”
GC2430 22 3/8” 29 3/8” 45 3/8” 29 3/8” 68 3/8” 29 3/8”
GC2436 22 3/8” 35 3/8” 45 3/8” 35 3/8” 68 3/8” 35 3/8”
3
Tools Required for Installation
GlassCrafters recommends the following tools to
properly and safely install your Mirrored Cabinets.
A. Safety Glasses -- should be worn at all times
B. Tape Measure
C. Level
D. #2 Phillips Head Screw Driver
E. Power Screw Driver
F. Electric Drill
G. 8mm 3/16” Masonry Drill Bit
H. 7/32” Drill Bit
I. Non Ammonia Household Glass Cleaner
J. Soft Paper Towels
Single Cabinet “RO” Rough Opening formula: Overall cabinet width less 5/8” = Rough Opening
Two Cabinets “RO” Rough Opening formula: Overall cabinet width less 5/8” plus the overall width of the second added cabinet = Rough Opening
Three Cabinet “RO” Rough Opening formula: Overall cabinet width less 5/8” plus the overall width of the two added cabinets = Rough Opening
Example: Model GC1630 combined with Model GC2430 = 15” less 5/8” = 14 3/8” plus 23” = 37 3/8” R.O. width.
Height: overall cabinet height less 5/8” = R.O. Height.
Important: Make sure you allow for a
minimum of 1” clearance above any obstruction
such as faucets, etc.
Rough Opening:
Note: Cabinet installs over nished wall with sheetrock
and/or tile nishes completed. 3/4” Flange on all sides of
the cabinet will cover the remaining space in the R.O.