Installation

9
A. Determine the desired height and use a level to
mark a horizontal line. Be sure to allow a minimum
clearance of 1” above any obstruction and plumbing x-
tures. Remember the base of the cabinet box is 3/4”
smaller than the face and the door.
For Surface Mounted Cabinets--
Rough Wiring to rear access
Plastic Bushing on the back of
the cabinet.
Access hole location is measured 5”
from left each of cabinet box and up
11/5/8” from the mounting bracket.
• Drill 1 1/2” through wall surface
• Pull wire through and allow at least
20” rough wiring for inserting in shelf
at installation.
Important:
Make sure you allow for a minimum of 1” clearance above
any obstruction such as faucets, etc.
Installing a Surface Mount Mirrored Cabinet Electric Option
11 5/8”
11 5/8”
4) Electric Connection when Mounting to wall:
Refer to pages 3- 6 and to Steps 1-5 on page 5
for detailed diagrams.
• Open front panel in Electric Option shelf using the
Allen wrench supplied. Do not lose the Allen screws
provided.
• Tip electric shelf cover down.
Take care not to scratch side wall of cabinet with
the edges of the shelf cover.
(Cover will stay in place with switch wiring.)
• Pull rough wiring through rear plastic bushing access
in the back of cabinet
.
• Lower onto wall bracket and tip up cabinet against wall.
(When Electrician has completed wire connections
be sure to replace shelf cover with Allen screws supplied.)
(If studs are not in
correct location for
support, drill and
install wall anchors.)
3) Locate studs and drill holes in
wall bracket at stud locations
2) Mark pencil line for base of cabinet
1) Keep minimum of 1” clear
above faucet
5) Slip Top Mounting Brackets into top groove
and position for studs. Mark and drill holes.
affix brackets with hand screw driver.
(Use wall anchors if necessary.)