Installation

6
RECESSED MOUNTING -- Determining the Rough Opening “RO” Dimension
Framing in new construction should follow these dimensions. Standard 2x4 studs and 1/2” sheetrock are shown in the illustrations.
For 6” deep models, a semi-recessed installation is required. For fully recessed 6” deep models, 2x6 studs are required.
Model Number Rough Opening Single Cabinet Rough Opening Two (2) cabinets Rough Opening Three (3) cabinets
Width Height Width Height Width Height
GC1630 14 3/8” 29 3/8” 29 3/8” 29 3/8” 44 3/8” 29 3/8”
GC1636 14 3/8” 35 3/8” 29 3/8” 35 3/8” 44 3/8” 35 3/8”
GC2030 18 3/8” 29 3/8” 37 3/8” 29 3/8” 56 3/8” 29 3/8”
GC2036 18 3/8” 35 3/8” 37 3/8” 35 3/8” 56 3/8” 35 3/8”
GC2430 22 3/8” 29 3/8” 45 3/8” 29 3/8” 68 3/8” 29 3/8”
GC2436 22 3/8” 35 3/8” 45 3/8” 35 3/8” 68 3/8” 35 3/8”
Single Cabinet “RO” Rough Opening formula: Overall cabinet width less 5/8” = Rough Opening
Two Cabinets “RO” Rough Opening formula: Overall cabinet width less 5/8” plus the overall width of the second added cabinet = Rough Opening
Three Cabinet “RO” Rough Opening formula: Overall cabinet width less 5/8” plus the overall width of the two added cabinets = Rough Opening
Example: Model GC1630 combined with Model GC2430 = 15” less 5/8” = 14 3/8” plus 23” = 37 3/8” R.O. width.
Height: overall cabinet height less 5/8” = R.O. Height.
RECESSED MOUNTING -- Rough Opening:
Note: Cabinet installs over nished wall with sheetrock and/or tile nishes com-
pleted. 3/4” Flange on all sides of the cabinet will cover the remaining space in
the R.O.
SPECIAL NOTE: When installing this cabinet over the finished surface that includes tile, the
location of the wire access hole must be repositioned to allow for the thickness of the tile
.
Rough Wiring:
Rough wire for this unit should ex-
tend 20” from either the left or right
wire access on the side of the cabi-
net to make the connections within
the Electric Shelf.
2x4
Framing
Shown
PLUMB
LEVEL
1
1
/2
dia.
Wire
Access
Hole
11
5
/
8
Recessed Cabinet Framing detail
wire access hole location
11
5
/
8
Rough Opening and Framing
Can Drill Rough Wiring
access from either side.
Allow 20” excess wire for
pull through.
Important:
Make sure you
allow for a
minimum of
1” clearance
above any
obstruction
such as
faucets, etc.
4” Deep
2
1
/2 +
1
1
/2
dia.
Wire
Access
Hole
11
5
/8
6” Deep
6” Deep
semi-recessed
Recessed Cabinet Framing side views showing
wire access hole location
1/2” Sheetrock
(example)
2x4 Framing
2x6 Framing
2x4 Framing
cabinet
flange
overlaps
3/4”
cabinet
flange
overlaps
3/4”
cabinet
flange
from
face of
finished
surface
(Sheetrock
plus tile)
2
1
/2 +
from
face of
finished
surface
(Sheetrock
plus tile)
4
1
/2 +
from
face of
finished
surface
(Sheetrock
plus tile)
Semi
recessed
showing
mirror
sidekit