perIsTalTIc pump adJusTmenT
unITs manuFacTured beFore January 2003 - cube relay TImer Type
1. Locate Peristaltic Pump in Glasswasher.
2. Locate Pump Control Cube Relay Timers.
3. Each pump has its own adjustment dial.
One for Detergent and one for Sanitizer.
Turn dial clockwise for faster pump speed
or counter-clockwise for slower pump
speed.
1
2
3
unITs manuFacTured aFTer January 2003 - pump conTrol module Type
1. Locate Peristaltic Pump in Glasswasher.
2. Locate Pump Control Module.
3. Each pump has its own adjustment dial.
One for Detergent and one for Sanitizer.
Turn dial clockwise for faster pump speed
or counter-clockwise for slower pump
speed.
1
2
3