Manual
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
19
TroubleshooTInG GuIde
Trouble or sITuaTIon cause remedy
A. Unit does not run 1. No power 1. Check power source.
(Power light “off.”)
2. Fill switch “off.” 2. Turn fill switch to “on” position.
3. Conveyor switch “off.” 3. Turn conveyor switch to “on”
position.
4. Glass stop switch in 4a. Glass holding glass stop arm in
Conveyor stop position. conveyor stop position.
4b. Front shield restricting glass
stop arm movement.
5. Defective fill switch. 5. Check if wash and/or rinse tanks
fill. If not, replace fill switch.
6. Defective conveyor switch 6. These switches are wired in
or glass stop switch. series. Test and replace
defective switch.
7. Wire connections poor, 7. Re-crimp and/or replace wire
loose, or broken. connection.
B. Conveyor runs but wash 1. Bad liquid level switch. 1. Check switch continuity.
and/or rinse tank(s) not Replace if necessary.
filling and detergent and/or 2. Liquid level out of adjustment. 2. Adjust liquid level pickup tube.
sanitizer pump is not operating 3. Water “off.” 3. Turn water “on.”
C. Conveyor runs but wash 1. Bad water valve. 1. Test valve, replace if necessary.
and/or rinse tank(s) 2. Loose pulley(s). 2. Tighten set screw(s). Note: The drive
not filling, and detergent motor pulley has an internal sleeve.
and/or sanitizer pump Set screw could be tightening against
is operating sleeve instead of motor drive shaft.
D. Conveyor moves 1. Loose belt. 1. Tighten belt by first loosening
intermittently the four motor mount towards
front and retighten bolts.
Caution: Excessive belt tension
could cause drive motor failure.
E. Water recirculating, 1. Obstruction in wash or 1. Remove obstruction.
conveyor not moving rinse area.
2. Conveyor not engaged 2. Rotate conveyor until it engages.
with conveyor drive shaft.
3. Defective drive motor. 3. Replace drive motor.
4. Defective of loose belt. 4. Replace or tighten belt.
F. Hot glasses at end 1. Rinse tank guide not 1. Replace rinse tank guide.
of cycle in place.
2. Plugged drain. 2. Clean drain.
3. Hot water supply connected 3. Replumb with cold water.
to cold water inlet.