wIrInG dIaGram unITs aFTer Jan. 2003
Wash Water
Recirculating
Pump
Rinse
Water
Recircu-
lating
Pump
Conveyor
Motor
YY
GG
WW
W
W
BB
B
B
W
W
Y
G
G
G
P
P
O
O
Cold Water
Inlet Valve
Rinse
Pressure Switch
On-Off
P
P
W
W
W
W
Hot Water
Inlet Valve
Br
Bl
Bl
Bl
Thermostat
Wash
Pressure Switch
Fill Switch
P
P
W
C
C
CNC
NC
NC
NO
Heating Element
Coil
Power Light
Relay
W
W
R
R(10 AWG)
B
B(10 AWG)
R(10 AWG)
B(10 AWG)
W
W
W
Detergent
Prime Switch
Sanitizer
Prime Switch
24V
AC
AC
24V
NC
NO
NC
C
Detergent Empty Sensor
Pressure Switch
"Check Chemical" Light
on Switch Panel
B
R
B(10 AWG)
R(10 AWG)
R/W(16 AWG)
Br/W(20 AWG)
O/W(20 AWG)
On-Off
Conveyor Switch Glass Stop Switch
Ground
Display
TemperatureTemperature
Display
24VDC Sanitizer Pump Motor
24VDC Detergent Pump Motor
Field
Connection
Box
RinseWash
R(20 AWG)
R/W(16 AWG)
P
C
Sanitizer Empty Sensor
Pressure Switch
C
R/W(16 AWG)
RR
R
O
Br
P
P PP
Sanitizer/Detergent
Speed Control
Module
O/W
O/W
Br/W
P
O/W(20 AWG)
Br/W(20 AWG)
Br/W
O/W = Orange W/White
R/W = Red W/White
Br/W = Brown W/White
R = Red
Bl = Blue
P = Purple
O = Orange
G = Green
Br = Brown
B = Black
LEGEND
Y = Yellow
W = White
O
O
O
Br
R+ B-
R+ B-
R+ B-
8 +
- 10
12 11
1
2
56 1413
Speed Control
Potentiometers
SAN
DET
7 +- 9
W B
W B
Secondary
120 VAC
50/60HZ
Primary
240 VAC
50/60 HZ
-208V or 240V,4KW
-1/12 HP,2.7A
-1/12 HP,2.7A
-1/140 HP,0.48A
Conveyor(Gear)Motor
Cold Water Solenoid
Hot Water Solenoid
Heating Element
Sanitizer Pump Motor
Detergent Pump Motor
Rinse Recirculating Pump Motor
Wash Recirculating Pump Motor
ELECTRICAL RATINGS
Relay
-85mA
-63mA
-85mA
-160mA
-160mA
Optional Transformer
For European Models
are 16 Gauge unless marked
equals 105 C.
otherwise. Wire Temperature Rating
o
120/208V or 120/240V, Single Phase
60Hz, 3 Wire, 20 Amp. All wires
R
B
Double Lines = 120 VAC 60 HZ Models
Dashed Lines = 240 VAC 50 HZ Models
Solid-Single Lines = 120/240 VAC 50/60 HZ Models
W O
BL
NOTE: Double lines specify
120 VAC 60 HZ wiring only,
dashed lines specify 240 VAC
50 HZ wiring only.