Glem - Installation and Operation Guide

INSTALLATION
This rangehood is designed for internal domestic household installation only. It is not intended for
use in a commercial environment. If installed in a commercial environment the warranty will be con-
sidered to be void.
The installation must be carried out by a licenced and experienced installer. If in doubt call Glem
Gas on 1300 307 917 for advice.
RANGEHOOD MOUNTING POSITIONS
Installl the rangehood centrally over the cooktop.
The recommended best functional minimum distance above the benchtop and the lowest point of
the rangehood 650mm above a gas cooktop. The recommended minimum height above an electric
cooktop is 600mm.
Installations above 750mm may reduce the effectiveness of the air extraction.
NOTE: Australian safety standards specify a minimum distance of 650mm above a gas cooktop and 600mm
above an electric cooktop. Installations must conform to the Australian/NZ Safety Standard
Decide where the ductwork will run between the hood and the ceiling.
A straight, short duct run will allow the hood to perform most efciently.
Long duct runs, elbows, and transitions will reduce the performance of the hood. Use as few
as possible. Larger ducting may be requir
ed for best performance with longer duct
runs.
Regulations concerning the discharge of air have to be met.
Install a wall cap. Connect round metal ductwork to cap and work back towards the hood
location. Use duct tape to seal the joints between ductwork sections.
INSTALLA
TION OF THE DUCTING
NOTE: When using expandable foil ducting make sure during installation that the ducting does
not come in contact with the stainless steel chimney as it can create vibration noise.
7
650 mm