Attach an adequate length of 150 mm round duct to the air outlet adapter and seal with duct
tape. Feed it through the previously cut hole in the ceiling. .
Carefully slide the stainless steel chimney down into the chimney bottom and then place the
chimney bottom into the recessed area on top of the hood.
Secure the chimney mounting bracket to the wall using (2) 4.2 x 30mm mounting screws and
anchors.
Raise the chimney top until its holes align with the holes in the chimney mounting bracket
located on the wall.
Level the hood and secure the chimney with 2 chimney bracket screws.
1.
2.
3.
4.
5.
150mm flexible ducting. Stretch out the
end and slide over ducting adapter
sleeve. It is a tight fit. Seal the joint with
duct tape.
Ducting adapter sleeve, locate into
slot on the discharge collar
Air Discharge Collar - snap in the 2 flaps.
Stainless Steel Chimney
Fix bracket to wall and attach chimney with 2 screws
Locate chimney into slot in the top of the rangehood
9
Duct tape, not supplied
Chimney mounting bracket
NOTE: In cases where the ceiling height means that the standard chimney (or flue)
does not
reach call Glem on 1 300 307 917 and check for chimney extension availability.