User Manual

244241,244242 www.globalindustrial.com . 13 .
Parameter
x/xy
Remark
244241
Setting
244242
Setting
P6.x
0-2
Communication format: 0=8N1, 1=7O1, 2=7E1
0
0
P7.xy
00-32
Resolution select:
00=500, 08=2400, 16=7500, 24=35000,
01=600, 09=2500, 17=8000, 25=40000,
02=750, 10=3000, 18=10000, 26=50000,
03=800, 11=3500, 19=12000, 27=60000,
04=1000, 12=4000, 20=15000, 28=70000,
05=1200, 13=5000, 21=20000, 29=75000,
06=1500, 14=6000, 22=25000, 30=80000,
07=2000, 15=7000, 23=30000, 31=100000
32 = factory preset N (0<N<100000)
10
10
P8.x
0-2
Division select: 0=1, 1=2, 2=5
2
0
P9.x
0-5
Decimal point in calibration:
0= x1, 1= x0.1, 2= x0.01; 3= x0.001; 4= x0.0001; 5= 10
2
1
P10.x
0,1
Calibration unit: 0=kg, 1=lb
0
0
P11.x
0-6
Weighing units enable:
0=only kg; 4=kg or lb:oz;
1=only lb; 5=lb or lb:oz;
2=only lb:oz; 6=kg, lb, or lb:oz
3=kg or lb;
3
3
P12.x
0-7
Power-on zero-point range:
0=calibration zero -point +1%FS;
1=calibration zero -point +2%FS;
2=calibration zero-point +5%FS;
3=calibration zero-point +10%FS;
4=calibration zero-point +20%FS;
5=calibration zero-point +50%FS;
6=calibration zero-point +100%FS;
7=No limitation
7
7
P13.x
0-9
Zero range for ZERO button:
0= Power-on zero-point +1%FS;
1= Power-on zero-point +2FS;
2= Power-on zero-point +3FS;
3= Power-on zero-point +4FS;
4= Power-on zero-point +5%FS;
5= Power-on zero-point +10%FS;
6= Power-on zero-point +20%FS;
7= Power-on zero-point +50%FS;
8= Power-on zero-point +100%FS;
9= No limitation
6
6
P14.x
0-2
Weight signal is in power-on zero point range, Choose
which data as current power-on zero point:
0= current weight ;
1= calibration zero-point;
2=switch-off zero-point
0
0