User Manual

244241,244242 www.globalindustrial.com . 14 .
Parameter
x/xy
Remark
244241
Setting
244242
Setting
P15.x
0-3
Weight signal is not in power-on zero point range,
Choose which data as current power-on zero point:
0= current weight ;
1= calibration zero-point;
2=switch-off zero-point;
3=continuously display “0ˉˉˉˉ”
3
3
P16.x
0-8
Zero tracking range:
0=0d, no tracking;
1=+0.25d; 2= +0.5d; 3=+1d; 4=+1.5d;
5=+2d; 6=+3d; 7= +4d; 8=+5d
6
6
P17.x
0-3
Data filter intensity:
0=very weak, 1=weak, 2=middle, 3=strong
2
2
P18.x
0-9
Check weight stability range:
0=+0.5d; 1=±1d; 2=+1.5d; 3=+2d; 4=+3d;
5=+4d; 6=+5d; 7=+6d; 8=+7d; 9=+8d
1
1
P19.x
0-9
Overload limit range:
0=FS+0d; 1=FS+9d; 2=101%FS; 3=102%FS;
4=105%FS; 5=110%FS; 6=120%FS; 7=150%FS;
8=200%FS; 9=No limitation
1
1
P20.x
0-2
Backlight on-off mode selection (if it is installed):
0= Backlight is always off;
1= Backlight is always on;
2= Backlight is auto on and auto off. It is auto off after 10s
when scale goes to stable and has no key operation, and
it is auto on when scale is unstable or there’s some key
operation.
2
2
P21.x
0-4
LCD contrast level
3
3