Instructions / Assembly

16
Support videos are available at: https://bluline.com/support/
Reverse Osmosis Membrane Replacement
RO versions (RO) (every three years)
a) Use the same procedure as above sec a-c.
b) Remove the RO stage from the clips. Disconnect the white tubing
from the RO housing cap.
c) Remove the cap from the housing by unscrewing it.
d) Using a pair of pliers, remove the RO element from the housing by
grasping the tube end and pulling it out.
e) Use RO filter replacement P/N GE50 (50gpd LG membrane). Insert
the element into the housing with double “o”-ring end going in
firsttoward the bottom of the housing. Make sure the “o”-rings are
sealed. Replace the cap. Reconnect the white tubing. Proceed as in
above sec-g.
Figure. 8 RO Membrane Installation