Reverse Osmosis Membrane Replacement
RO versions (RO) (every 3 years)
a) Use the same procedure as above sec a-c.
b) Remove the RO stage from the clips. Disconnect the white tubing
from the RO housing cap.
c) Remove the cap from the housing by unscrewing it.
d) Using a pair of pliers, remove the RO element from the housing by
grasping the tube end and pulling it out.
e) Use RO filter replacement P/N 50GPD. Insert the element into the
housing with double “o”-ring end going in firsttoward the bottom
of the housing. Make sure the “o”-rings are sealed. Replace the
cap. Reconnect the white tubing. Proceed as in above sec. g.
Figure. 8 RO Membrane Installation