Datasheet

PROPRIETARY INFORMATION:
PROPRIETARY OF GLOBTEK, INC. ANY REPRODUCTION, DISCLOSURE OR
USE OF THIS DRAWING, IN WHOLE OR IN PART, IS HEREBY
PROHIBITED EXCEPT AS SPECIFIED IN WRITING BY GLOBTEK, INC.
REVISION
REV
A
B
DESCRIPTION
INITIAL RELEASE, RFS. 19933, EM
UPDATE TO LATEST VERSION TEMPLATE, RFS. 20681, SO
DATE
11/09/10
04/06/11
APPROVED
HM
HM
DASH
NO.
TABULATION BLOCK
TOLERANCES:
FSCN No.:
G, Y
SIZE
A
SCALE: NONE
INIT.BY: SO
DATE:
04/06/11
DRAWN: NF
DATE:
04/06/11
APRVD : HM
DATE:
04/06/11
PART NO REV.
DESCRIPTION
NOTES
www.globtek.com
DECIMALS
.xx +/- 0.1
.xxx +/- .005
ANGULAR
+/- 1
o
MILLIMETERS
.xx +/- 0.3
.xxx +/- .013
ANGULAR
+/- 1
o
186 Veterans Dr. Northvale, NJ 07647
Tel. 201-784-1000 Fax 201.784.0111
MODEL NO:
GTM91110P24012-FA-S
REV.
B
PART NO:
GTM91110P24012FSIM(R
SHEET 1 OF 7
DWG TITLE:
OPEN FRAME SWITCHER, 240 WATT MAXIMUM, SINGLE OUTPUT,
UNIVERSAL AC INPUT, MEDICAL AND ITE, CLASS I
Limitation of Use:
Globtek product are not authorized for use
as mission critical components in life sup-
port, hazardous environment, nuclear or
aircraft applications without prior written
approval from the CEO of Globtek Inc.
Contents of this document are subject to
change without prior notice
Foot Note:
Globtek Inc. will not be liable for the
safety and performance of these power sup-
plies if unauthorized access and repair
occurs. End user should consult applicable
UL, CSA or EN standards for proper instal-
lation instructions
FEATURES
· 240 WATTS IN 3 x 5 x 1.75 mm FOOTPRINT FOR OPEN FRAME VERSION
· OPTIONAL PERFORATED ENCLOSURE AVAILABLE
· UNIVERSAL INPUT WITH ACTIVE POWER FACTOR CORRECTION
· MEDICAL, ITE AND PoE GRADE VERSIONS
· EN60601-1-2, EN55022, EN55024, EN61000-3-2/3 COMPLIANT
· BUILT-IN EMI FILTER
· REMOTE OUTPUT SENSING OPTION
· OVERVOLTAGE PROTECTION
· CONSTANT CURRENT OVERLOAD PROTECTION
· THERMAL OVERLOAD PROTECTION
· FACTORY CONFIGURABLE OUTPUT FROM 12V TO 55V IN 0.1V INCREMENTS
· OUTPUT ISOLATED FROM EARTH GROUND BY 2121VDC
· SINGLE OUTPUT PLUS 12V FAN OUTPUT VOLTAGE
· DC INPUT OPTION, 130VDC TO 380 VDC
· CLASS I OR CLASS II VERSIONS
1. ELECTRICAL SPECIFICATIONS:
INPUT
INPUT RANGE 90-264 VAC
INPUT LINE FREQUENCY 47-63Hz
INPUT CURRENT 4A RMS MAXIMUM @ 90VAC
INRUSH CURRENT
60A MAXIMUM, COLD START @ 25°C, 115VAC INPUT, 120A AT 240VAC LOAD
EFFICIENCY 85% TYPICAL AT FULL LOAD, 230Vac INPUT
POWER FACTOR 0.99 TYPICAL AT FULL LOAD, 230Vac INPUT
TURN-ON DELAY 5 SECONDS MAXIMUM @ 115VAC INPUT
INPUT LINE PROTECTION MOV TRANSIENT PROTECTED. INPUT LINE FUSE PROVIDED ON-BOARD
SOFT START STANDARD ON ALL MODELS
OUTPUT
OUTPUT VOLTAGE 12V
OUTPUT CURRENT 20A MAXIMUM (SEE NOTE 8)
MAXIMUM POWER 240 WATTS MAXIMUM WITH 20 CFM AIRFLOW OPEN FRAME VERSION
150 WATTS MAXIMUM WITH CONVECTION COOLING OPEN FRAME VERSION
LOAD REGULATION ± 2% MEASURED AT THE CONNECTOR SIDE
LINE REGULATON ± 0.5% MEASURED AT THE CONNECTOR SIDE
OUTPUT RIPPLE VOLTAGE +/-1% MAXIMUM OF NOMINAL OUTPUT VOLTAGE
(PEAK TO PEAK) MEASURED AT 20 MHz BANDWIDTH WITH 0.1µf CERAMIC CAPACITOR
IN PARALLEL WITH10 µf ELECTROLYTIC CAPACITOR CONNECTED
AT THE END
OF THE OUTPUT CONNECTOR.
TURN ON/OFF OVERSHOOT 5% MAXIMUM, 1mS RECOVERY TIME
HOLD-UP TIME 8 mS @ 240W LOAD, 10mS@200W LOAD, 16mS@150W LOAD
AT 115VAC INPUT

Summary of content (7 pages)