5.4.2 Connecting units
Cables
An indoor unit is connected to an outdoor unit by means of a 2 coaxial cables, one is for
downstream and another one for upstream signal, 1 Ethernet cable and 1 power supply
cable. Cable length should not exceed 90m.
Recommended cables:
Coax cable 50ohm Ecoflex 15
Ethernet cable Belden 7918A
Power supply cable Helukabel JZ-600 4G4 (MAX outer diameter is 14,5mm)
Coax cable 75 ohm - RG6 T60
Connectors Outdoor (Sector antenna) side
N-plug, male, solderless for Ecoflex 15
RJ45 connector for Ethernet cable; for Antenna is used RJ45 connector with
AMPHENOL RJF 6B (A code)
Power connector M23, Male thread
Connectors Indoor side
N-plug, male, solderless for Ecoflex 15
RJ45 connector for Ethernet cable;
Power connector M23, Female thread
F-connector - Cabelcon F-56-CX3 4.9 or PPC EX6
Tools and Equipment
24mm wrench
Utility knife
Long nose pliers
DMC M320 crimp tool
RJ45 crimp tool
19mm wrench
Small metal saw
F-connector crimp tool
75ohm coax cable stripping tool
Cutting pliers
19mm spanner