5.4.5 M23 Power connector installation manual (indoor CPS side)
Push clamp (Pos. 1), reducing sleeve (Pos. 2) with sealing ring (Pos. 3) on the cable.
Strip cable outer sheath 40 mm (Pos. 4)
Strip the wires (7mm) and crimp on contacts with crimping tool DMC M320
Clip contacts laterally into the insert sleeve until “click” (Pos. 12).
Insert sleeve and clamp (Pos. 14) tighten until it stops. wrench size 24mm
Figure 23: M23-connector installation manual CPS