5.4.7 RJ45 connector installation with AMPHENOL RJF 6B
Cut cable to required length. Remove the outer jacket (3,8cm) with knife or tool.
Assemble Amphenol connector as shown on above schematics. Code A is used.
Pull the wire braid back over the outer jacket. Trim off the clear plastic jacket.
Untwist and separate all of the conductor pairs.
Arrange the conductor in the order shown:
1. White/orange
2. Orange
3. White/green
4. Blue
5. White/blue
6. Green
7. White/brown
8. Brown
Bring the sorted conductor together, holding tightly between the thumb and forefinger.
Recheck to ensure the wiring sequence is correct. Cut the wires at 90° angle about 1.27
cm (half inch) from the end of the jacket.
Insert the conductors into the plug. Hold the plug with cooper contacts facing up and
locking tab facing down. In this position, the orange/white conductor should be the first
conductor on the left.
Crimp the plug using the crimp tool for Ethernet connectors.
Figure 25: RJ45 connector installation manual