User manual

30
Sample computation for checking and
determining dosage of spray com-
pound
Bases:
Spraying pressure 1.5 bar
Nozzle 1 mm hollow cone
Spraying height 50 cm
Dosage 0.5 % (see pesticide
manufacturer’s in-
structions)
This means:
Quantity required 0.42 l/min
Spraying width 50 cm
Angle of spray 55°
Quantity of spray compound
per m
2
: 0.06 l, = 600 l/ha
(see pesticide manufacturer’s
instructions)
To mix 1 l spray compound:
1 l water + 5 ml compound
(5 ml = 0.5 % of 1 litre)
With a spraying width of 50 cm, a length of
2 m equals a sprayed area of 1 m
2
.
Speed of spraying:
Quantity sprayed per minute x distance
Quantity of spray per m
2
0.42 l x 2 m
min. x 0.06 l
= 14 m/min.
The figures on which this sample computa-
tion of the dosage and the quantity of spray
compound required per m
2
are based have
been assumed for that purpose.
When using the sample computation, the
figures given by the manufacturer of the re-
spective spray compound must be used. If
other nozzles are used, the appropriate tech-
nical data must be taken from the separate
sheet 976 559 (Optional Accessories
and Nozzle Table) ** and used in the
computation.
Spraying
To obtain as even a spray pressure and as
long a spray cycle as possible, set the
pressure regulator on the quick close valve
(10 litre units only)
at the minimum per-
missible pressure e.g. 1.5 bar
(see
Fig. ).
To start the spraying process push the
operating lever on the quick close valve
down. Releasing the operating lever will
stop the spraying process immediately.
If the pressure in the tank falls below the
minimum permissible pressure, work the
pump a little to ensure an even spray. The
optimum spraying pressure for the 1 mm
hollow cone spray is between 1.5 and 3
bar.
When spraying, ensure that the plants are
wetted evenly.
Pay attention to the direction of the wind!
Do not spray into the wind.
The optimum distance from the nozzle to
the plant being sprayed is between 40
and 50 cm.
When using special spraying lances (ex-
tension lances, wide spray lances etc.),
set the pressure higher on the pressure
regulator.
18