21 221564F
Diagram 11.2
6532
PRESSURE TEST
POINT
ELECTRICAL
CONNECTIONS
ELECTRICAL
CONNECTIONS
PROTECTIVE CAP
Repeated pressing of the 'Mode' button gives the display
sequence shown in diagram 11.4.
If a different option is required, repeatedly press the Mode
button until the required symbol is shown, and then press and
hold the Mode button for two seconds. The decimal point will
flash to confirm selection.
Note: If left the display reverts to show boiler temperature after
approximately two minutes.
Temperature Display
The boiler normally shows the operating temperature of the unit
on the digital display. However, because the display consists of
only one digit, temperature is represented in blocks of ten
degrees as follows.
CONTROL
DOOR
DISPLAY TEMPERATURE RANGE (°C)
0 Min - 5
1 6-15
2 16 - 25
3 26 - 35
4 36 - 45
5 46 - 55
6 56 - 65
7 66 - 75
8 76 - 85
9 86 - Max
6566
Diagram 11.3
6533
BRASS
LUGS
The decimal point after the digit signifies that the boiler is firing.
This information is also supplied on the inside of the control
door.
11 Commissioning
Temperature Options
There are four domestic hot water and four central heating
options to choose from. These options are shown on the digital
display by repeated pressing of the Mode button. The sequence
is shown in diagram 11.4. The selected options are indicated by
a flashing decimal point.
Only one domestic hot water and one central heating option can
be selected at any one time.
For adaptive control, see section 11.10.