36
221564F
14 Replacement of Parts
Because of our constant endeavour for improvement, details may vary slightly from those shown in these instructions.
Diagram 14.8
6565
AIR PRESSURE
SWITCH
SENSING
TUBE
ELECTRICAL
CONNECTIONS
CLIPS
Key No. Part No. Description GC Part No.
1 801056 Gas control valve (80) E24293
1a 801145 Gas control valve (100) E24434
2 801064 Automatic control module (80) E24300
2a 801147 Automatic control module (100) E24436
3 801029 Ignition lead (80) E24243
3a 801140 Ignition lead (100) E24418
4 801112 Electrode E24371
5 801049 Pump E24288
6 801052 Three way valve head E24291
7 432875 Mini expansion vessel 360113
8 801034 Heating flow thermistor /Heating return thermister E24250
9 208214 Water inlet filter 281359
10 801120 Domestic hot water thermistor E24381
11 801074 Air pressure switch E24309
12 801039 Burner (80) E24257
12a 801142 Burner (100) E24426
13 801087 Injector (80) E24336
13a 801154 Injector (100) E24449
14 801040 Fan (80) E24259
14a 801040 Fan (100) E24259
6557
1
2
3
4
5
6
7
8
9
10
11
12
13
14
14.25 Control Door
Open the control door and pull the brass lugs out of their
locations in the fascia, see diagram 11.3.
14.26 Mini Expansion Vessel
If the mini expansion vessel option is fitted it can be replaced by
the following method.
Refer to section 12.10 and drain the boiler hot water circuit.
Remove the right hand casing panel as described in section
12.8.
Remove the mini expansion vessel.
Fit new vessel using a suitable thread sealant, see diagram 6.3.
14.27 Spare Part LIst