Instruction Manual
0020085231_02 - 05/10 - Glow-worm
- 30 -
13.2.2 After Sales Service settings
• Press for more than 7 seconds on the button to
access the conguration menu. The screen displays "0".
• Press on button
or under the symbol and enter the
After Sales Service password.
• Press on
to validate. The screen displays the
parameter "00" and its value "XX”.
• Press on button
or under the symbol to access the
parameter to modify.
• Press on button
or under the symbol to modify the
value of the parameter.
• Repeat the process for each parameter modied.
• Press for more than 3 seconds on the button
to exit
the conguration menu.
Code Parameter Unit Description
Factory
setting
Modiable
parameter
d.08 Current state of the 230V room thermostat -
230V room thermostat :
0 = open (no heating),
1 = closed (heating mode).
- no
d.09 Flow temperature set point from external eBus control °C External eBus set value. - no
d.10 Heating pump status -
0 = off
1 = on
- no
d.16 Current state of the 24V room thermostat °C
0 = open (no heating),
1 = closed (heating mode)
- no
d.17 Flow or Return temperature monitoring °C
Temperature regulation on ow (radiator) or return
(under-oor heating) temperature sensor.
0 yes
d.21 Warmstart status -
0 = warmstart function disabled
1 = warmstart activated
- no
d.22 DHW demand active (tapping) -
0 = off
1 = on
- no
d.23 Central heating mode -
0 = CH not available (summer mode)
1 = CH available (winter mode)
- no
d.25 Warm start -
Loading enabled or disabled by Appliance Interface
or Ebus or external controls.
- no
d.33 Speed setpoint of fan rpm
Fan speed is displayed between 0 and 99.
Multiply the displayed value by 100.
- no
d.44 Digitalized ionisation voltage V Display the digitalized ionisation voltage - no
d.68 Unsuccessfull ignitions at rst attempt -
Display the number of unsuccessfull ignitions at rst
attempt.
- no
d.69 Unsuccessfull ignitions at second attempt -
Display the number of unsuccessfull ignitions at
second attempt.
- no
d.80 Operating hours in heating mode h
Display the number of operating hours in heating
mode. Multiply the displayed value by 100.
- no
d.81 Operating hours in domestic hot water mode h
Display the number of operating hours in domestic
hot water mode. Multiply the displayed value by 100.
- no
d.82 Number of burner starts in heating mode -
Display the number of burner starts in heating
mode. Multiply the displayed value by 100.
- no
d.83 Number of burner starts in DHW mode -
Display the number of burner starts in DHW mode.
Multiply the displayed value by 100.
- no
d.93 Device Specic Number -
Select the product code of the appliance:
24cxi = 15
30cxi = 22
35cxi = 17
15
22
17
yes
d.96 Factory reset -
All parameters stored in EEPROM (main board +
appliance interface) are reset to factory settings if
this function is activated.
0 = deactivated
1 = activated
0 yes
INSTALLATION