15. Tecnical data
Protective conductor resistance:
Measuring range 0 ... 2 Ω
Display range 0 ... 1.000 Ω
Resolution 1 mΩ
Error ± 5 % ± 10 digit
Measurement current min. 200 mA DC (+/–)
Insulation resistance:
Measuring range 200 kΩ ... 200 MΩ
Display range 0.200 ... 200 MΩ
Resolution 0.001 kΩ
Error ± 5 % ± 10 digit
Measurement voltage min. 500 V DC
Substitute leakage current:
Measuring range 0 ... 20 mA
Display range 0 ... 20 mA
Resolution 0,001 mA
Error ± 5 % ± 10 digit
Measurement voltage 220 V AC
Protective conductor current, direct:
Measuring range 0 ... 5 mA
Display range 0 ... 5 mA
Resolution 0.001 mA
Error ± 5 % ± 10 digit
Touch current, direct:
Measuring range 0 ... 1 mA
Display range 0 ... 1 mA
Resolution 0.001 mA
Error ± 5% ± 10 digit
Protective conductor current, differential current:
Measuring range 0 ... 5 mA
Display range 0 ... 5 mA
Resolution 0.001 mA
Error ± 5 % ± 10 digit
Touch current, differential current:
Measuring range 0 ... 1 mA
Display range 0 ... 1 mA
Resolution 0.001 mA
Error ± 5% ± 10 digit
Operating manual for the TG uni 1 appliance tester
Technical data