Go P ower! Man ual Po Manual GP-600 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.
Go Power! Modified Sine Wave Inverter Owner’s Manual Table of Contents 1. INTRODUCTION 3 2. SPECIFICATIONS 3 3. FEATURES 4 4. INSTALLATION 5 5. OPERATION 8 6. OPERATING LIMITS 8 7. TROUBLESHOOTING 9 8. MAINTENANCE 10 9. WARRANTY 10 Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Toll Free Tel: 866-247-6527 Toll Free Fax: 866-607-6527 Email: info@gpelectric.com Rev2.0 GPModifiedSWInstallGuide.
Go Power! Modified Sine Wave Inverter Owner’s Manual Low battery alarm on all the time, LED indicator is red. Low input voltage. Have qualified service technician check and replace. Poor DC wiring, poor battery condition. Make sure that inverter is connected to 12 V battery. Check regulation of charging system. Recharge battery. Use proper cable and make solid connections. Use new battery. Go Power! Modified Sine Wave Inverter Owner’s Manual 1.
Go Power! Modified Sine Wave Inverter Owner’s Manual Go Power! Modified Sine Wave Inverter Owner’s Manual The power inverter will also shut down if the input voltage exceeds 15 V. This protects the inverter against excessive input voltage. Although the power inverter incorporates protection against over voltage, it may still be damaged if the input voltage is allowed to exceed 20 V. 3. Features 3.1 Front view – GP-600 c) Power d) Fault 7. Troubleshooting 7.
Go Power! Modified Sine Wave Inverter Owner’s Manual 5. Operation To operate the power inverter, turn it on using the ON/OFF switch on the front panel. The power inverter is now ready to deliver AC power to your loads. If you are operating several loads from the power inverter, turn them on separately after the inverter has been turned ON. This will ensure that the power inverter does not have to deliver the starting currents for all the loads at once.
Go Power! Modified Sine Wave Inverter Owner’s Manual 4.2 Hook-up and testing To hook-up the inverter please follow these guidelines: Caution Do not connect this inverter and another AC source (generator or utility power) to the AC wiring or AC loads at the same time. Doing so will destroy the inverter and void the warranty, regardless whether the inverter is switched on or off.