Product Manual

gpelectric.com | [page 37]
Electrical Specication Item
Model No.
GP-ISW1500-12 GP-ISW1500-24
Input
Characteristics
Voltage 12VDC 24VDC
Input Over Voltage Protection
(1)
16.5 ± 0.3VDC 33 ± 0.5VDC
Input Under Voltage Protection 10.5 ± 0.3VDC 21 ± 0.5VDC
Voltage Range 10.5~16.5 VDC 21~33 VDC
No Load Current
1.8A @12VDC 1.0A @24VDC
Power Saving Mode <0.1A @12VDC <0.05A @24VDC
Output
Characteristics
Continuous Output Power 1500 VA (± 3%)
Maximum Output Power
(1Min)
> 1500 VA~1730VA (100%~115%)
Surge Power (1Sec) <2650 VA
Frequency 50 / 60 Hz ± 0.5% (Dip Switch Selectable)
Output Voltage
100 / 110 / 115 / 120 VAC (± 5%)
(Dip Switch Selectable)
Efciency Max.
91%
92%
Short-Circuit Protection 1 Sec Shutdown
Output Waveform Pure Sine Wave (THD < 5%@ Normal Load) (2)
Signal and
Control
Remote Controller Panel Unit GP-SWR-A / GP-ISW-R (optional)
LED Indicator Red / Orange / Green LED
Dry Contact Terminal By a relay
Remote Control Terminal 6-port Green terminal (for inverter ON / OFF)
Protection
Input Protection Over / Under Voltage, Reverse Polarity (Internal Fuse)
AC Output Protection Short-Circuit, Overload
Others
Over / Under Temperature Protection
(by Heat Sink Temperature +80°C/-20°C)
Environment
Operating Temp. -20 °C~40 °C (3)
Storage Temp. -30 °C~70 °C
Storage Temp. & Humidity 10 ~95% RH
Safety & EMC
Safety Standards Certied UL 458 (6th Edition)
EMC Standards Certied FCC class B
Dimension(WxHxD) 248mm X 83mm X 421mm
Weight 4.14 KG
Cooling Temperature & Load Controlled Cooling Fan
SPECIFICATIONS