User Manual
[page 10] | gpelectric.com
®
GP-PWM-10-FM/GP-PWM-30-SB SOLAR CONTROLLER
When the GP-PWM-10-FM or GP-PWM-30-SB are connected to the battery, the controller will go into Power Up mode.
Icons Displayed: All segments of the numerical display; backlight blinks.
(The diagrams on the following pages apply to both the GP-PWM-10-FM and the GP-PWM-30-SB).
Depending on the battery voltage when the controller Power Up occurs, the controller may do a Boost Charge or quickly go into Float Charge.
The Charging Prole selected will commence the following day after a Power Up (refer to the Charging Prole Chart below for more details).
To select the battery charging prole, press and hold the B Button. This will cause
the current battery type to ash.
Then, press the B Button to toggle through the prole options: Sealed/Gel, AGM/
LiFePO4 or Flooded.
To conrm the battery prole, press and hold the A Button for 3 seconds.
Non-volatile memory: Any settings made on the GP-PWM-10-FM will be saved
even when the power has been disconnected from the controller.
Refer to the Battery Charge Prole Chart below for details on each prole.
BATTERY TYPE SEALED /GEL AGM FLOODED LFP
Float Charge @ 25°C: 13.7V (+/- 0.1V) N/A
Bulk/Absorption Charge @ 25°C:
Set to 30 minutes every morning.
Applied for 2 hours if the battery voltage
drops below 12.3 volts.
14.1V (+/- 0.1V) 14.4V (+/- 0.1V) 14.4V (+/- 0.1V) N/A
Equalization Charge @ 25°C:
Applied for 2 hours every 28 days and if
the battery voltage drops below
12.1 volts.
N/A N/A 14.9V (+/-0.1V) N/A
Absorption Charge voltage for LiFe-
PO4:
Set to 30 minutes every morning
N/A 14.4VDC
Float Charge voltage for LiFePO4: N/A 14.0VDC
If a charging cycle is unable to complete in a single day, it will continue the following day. The terms SEALED/GEL, AGM, FLOODED and LFP are
generic battery designations. Choose the charging prole that works best with your battery manufacturer’s recommendations.
If PV power is insucient or too many loads are drawing power from the battery, the controller will not be able
to charge the battery to the target charging voltage.
5.3.1 POWER UP
5.3.2 SETTING THE BATTERY CHARGING PROFILE
5.3.3 BATTERY CHARGING PROFILE CHART
5.3 OPERATING INSTRUCTIONS