User Manual

gpelectric.com | [page 7]
®
GP-PWM-10-FM/GP-PWM-30-SB SOLAR CONTROLLER
5.1.3 BATTERY TYPE
Both controllers are suitable for use with lead acid and lithium batteries (vented, GEL, LiFePO4 (LFP) or AGM type).
To protect the battery against over-discharge this function automatically switches o󰀨 the USB output port when battery voltage is lower
than 11.0 VDC. As soon as the battery reaches a voltage of 12.8 VDC the USB output port is switched on again.
DESCRIPTION VALUE DIMENSIONS (H X W X D):
Model GP-PWM-10-FM
149 x 98 x 32 mm
5.87 x 3.86 x 1.26 in
Weight: 260 g / 9.2 oz
Maximum Wire Gauge:
#4 AWG
Warranty: 5 years
• PWM Charging
• 4 Battery Charging Proles
• 4-Stage Charging
• Monthly Equalize Option
Displays Charging Current, Battery Voltage,
Battery State of Charge, and Amp Hours
Charged Since Last Reset
• Reverse Polarity Protected
• Temperature Compensated
• RoHS Compliant, Environmentally Safe
Accepts up to 160 Watts of Solar at 12 Volts
Nominal System Voltage 12 VDC
Range of Battery Input Voltage 9 – 15.5 VDC
Maximum Solar Continuous DC
Charge Current Input
12.5 ADC
Charging Output DC Voltage Range 9 – 14.9 VDC
Maximum Solar DC Input Voltage 35 VDC
Maximum Series Fuse or
Circuit Breaker Solar/Battery
15 A
Operating Consumption
(Display backlight on)
15 mA
Operating Consumption
(Display backlight o󰀨)
6 mA
Battery Types Supported
Vented & Sealed Lead Acid (GEL, AGM, Flooded, etc.).
Lithium (LiFePO4)
Bulk/Absorption Voltage
(Sealed/GEL, AGM/LFP, Flooded)
14.1/14.4/14.4 VDC (25°C / 77°F), 30min / Day
or 2hr if battery voltage < 12.3 VDC
Float Voltage 13.7V (25°C / 77°F), 14.0V (LFP)
Equalization Voltage
14.9V (25°C / 77°F), 2h / 28 Days
or if battery voltage < 12.1 VDC
Temperature Compensation - 24mV/ºC / -13mV/ºF
USB charger 5V, 1500mA
5.1.4 LOW VOLTAGE DISCONNECT FUNCTION (USB PORT)
5.1.5 REGULATORY INFORMATION
5.1.6 SPECIFICATIONS