Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX ________________________________________________ Owner’s Manual
GPC-35-MAX / 45-MAX / 55-MAX / 75-MAX / 100-MAX ___________________________________________________________ Table of Contents Important Safety Instructions 2 Features 3 Installation Guidelines 5 Warranty 8 1.0 Important Safety Instructions Warning: Before you install and use your Go Power! Smart Converter/ Charger, be sure to read these safety instructions. 1.1 General Safety Precautions 1. Do not expose the GP Smart Charger to rain, snow, spray, bilge, or dust.
GPC-35-MAX / 45-MAX / 55-MAX / 75-MAX / 100-MAX ___________________________________________________________ 2.0 Features The Go Power! Smart Converter Charger (GPC) series power converter / battery charger converts 120 V nominal AC to 13.6 V DC. As a power supply, its tightly controlled regulation allows the user to operate any 12 V nominal DC load up to the converter’s rated output current.
GPC-35-MAX / 45-MAX / 55-MAX / 75-MAX / 100-MAX ___________________________________________________________ SPECIFICATIONS* DC Output Voltage (No Load) approx. Output Voltage Tolerance (No Load) Output Amperage, Max Continuous Output Voltage (Full Load) approx.
GPC-35-MAX / 45-MAX / 55-MAX / 75-MAX / 100-MAX ___________________________________________________________ 2.5 120 Volt AC Input Plug the GPC AC input cord into a 120 V 3 wire grounded source. See chart for maximum current draw and required input voltages. 2.6 Reverse Polarity Fuses The GPC is protected against reverse polarity on the DC output. If a battery or the GPC is hooked up incorrectly, the fuses will blow and can be easily replaced.
GPC-35-MAX / 45-MAX / 55-MAX / 75-MAX / 100-MAX ___________________________________________________________ 3.4 Reverse Polarity Fuses The GPC is protected against reverse polarity on the DC output. If a battery or the GPC is hooked up incorrectly, the fuses will blow and can be easily replaced. Always use the same size and style fuse that came with the converter. To change the fuses, use a screwdriver to loosen the screws and remove the fuses. Always replace the fuses with the same type and rating.
GPC-35-MAX / 45-MAX / 55-MAX / 75-MAX / 100-MAX ___________________________________________________________ 4.1.5 Voltages The charging voltages used to charge the battery during the three stages differ depending on the voltage of the battery being charged. If you need to know the various voltages, you can calculate them as follows: Charging Stage Voltage Charge per Cell Bulk Charge 2.46 Absorption Charge 2.36 Float Charge 2.26 1. 2. Determine the number of cells your battery has.
GPC-35-MAX / 45-MAX / 55-MAX / 75-MAX / 100-MAX ___________________________________________________________ 5.0 Warranty 5.1 Go Power! 2 Year Limited Warranty Go Power! provides the following limited 2 year warranty (“warranty”) coverage as applicable to the purchaser (“Purchaser”) of the Go Power!™ branded product (“Product”) directly from Go Power!™ The following constitutes the terms and conditions of that limited warranty. 5.1.
GPC-35-MAX / 45-MAX / 55-MAX / 75-MAX / 100-MAX ___________________________________________________________ 5.1.2 What the Go Power! Warranty Does Not Cover The Go Power! warranty does not provide coverage for the following which are expressly excluded from the above warranty: Failure due to normal wear and tear of the Product. Failure caused by separate computer software supplied with or associated with a Go Power! Product.
GPC-35-MAX / 45-MAX / 55-MAX / 75-MAX / 100-MAX ___________________________________________________________ to the claim. IN NO EVENT SHALL GO POWER! BE LIABLE FOR PUNITIVE, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES WHETHER FORSEEABLE OR NOT INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS OR REVENUES, LOSS OF USE OF GOODS, OR LOSS OF BARGAIN. The Warranty set out above is the sole warranty granted by Go Power! with respect to the Product.
GPC-35-MAX / 45-MAX / 55-MAX / 75-MAX / 100-MAX ___________________________________________________________ 5.3 Additional Information Unless approved by Go Power! management, all product shipped collect to Go Power! will be refused. 5.4 Out of Warranty Items Go Power! electronic products are non-repairable, Go Power! does not perform repairs on its products nor does it contract out those repairs to a third party. Go Power! does not supply schematics or replacement parts for any of its electronic products.
GPC-35-MAX / 45-MAX / 55-MAX / 75-MAX / 100-MAX ___________________________________________________________ © 2014 GO POWER! By Carmanah Technologies gpelectric.