SDS

SDS - NCM18650
REVISION DATE:2015-1-27
Cold water and dry powder in large amount are applicable. Use metal fire extinction power or
dry sand if only few cells are involved.
Special hazards arising form the chemical
May form hydrofluoric acid if electrolyte comes into contact with water. In case of fire, the
formation of the following flue gases can not be excluded: Hydrogen fluoride(HF), Carbon
monoxide and carbon dioxide.
Protective equipment and precautions for firefighters
Wear self-contained breathing apparatus and protective suit.
Personal precautions
Use personal protective clothing.
Avoid contact with skin, eyes and clothing.
Avoid breathing fume and gas.
Environmental precautions
Do not discharge into the drains/surface waters/groundwater.
Methods for cleaning up/taking up.
Take up mechanically and send for disposal.
Handling
Advice on safe handling
Avoid short circuiting the cell. Avoid mechanical damage of the cell. Do not open or
disassemble.Keep away from open flames, hot surfaces and sources of ignition.
Storage
Requirements for storage rooms and vessels
Storage at room temperature(approx.20°C) at approx.20~60% of the nominal
capacity(OCV approx.3.6~3.9V/cell).
Keep in closed original container.
3
6. ACCIDENTAL RELEASE MEASURES
7. HANDLING AND STORAGE
8. EXPOSURE CONTROLS/PERSONAL PROTECTION