Installation Guide

Copyright © 2015 Nortek Security & Control LLC 23
Clock Menu
Use the clock menu to set thermostats internal clock.
Figure 26. Clock Setup
Seƫ ng the Clock
1. Press any bu on to take thermostat out of sleep mode.
2. Press FAN bu on for 5 seconds un l, SETUP appears in status display line.
3. Use  bu ons to select CLOCK in status display line.
4. Press SELECT, DAY will be displayed
5. Press  bu ons, TIME will be displayed.
6. Use the  bu ons to select the current me.
7. Press SELECT, DONE, DONE.
INFO Menu
The INFO menu displays informa on about the thermostat. Use the  bu ons to scroll through
the various items.
• MODEL NTBZ48
• VERSION Thermostat rmware version.
• ZWAVE Z-Wave rmware version.
NODE ID Z-Wave Node ID.
HOME ID Z-Wave Home ID.
SYSTEM TYPE displays current System Type se ng.
If System Type = Standard, FAN TYPE displays current Fan Type se ng.
If System Type = Heat Pump, CHANGEOVER TYPE displays current Change Over se ng.
• Ba ery xx% = Ba ery Level (If ba ery powered)
MODE
FAN
Select
Done
CLOCK
USE THE 
BUTTONS TO CHANGE
TO THE DESIRED MENU
ITEM, THEN PRESS
SELECT
MENU CHOICES
ARE DISPLAYED IN THE
STATUS DISPLAY LINE
PUSH AND HOLD
FOR 5 SECONDS
76