User’s Guide GS220
Disclaimer Seller reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult seller to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of seller.
Table of Contents Introduction ............................................................................................. 1 Components ..................................................................................................... 1 Maintenance ..................................................................................................... 1 Caution and Serial Number Labels ................................................................... 2 Cable Installation and Removal ....................
Standard Suffix Characters ............................................................................ 17 User Configurable Suffixes, All Data .............................................................. 18 Code Formatting UPC/EAN Formatting ..................................................................................... 19 Keyboard Enable Keyboard Emulation ........................................................................... 21 Code Bytes Usage Code Bytes 0-9..............................
Introduction Components Item No. Description 1 Red Output Window (Laser Aperture) 2 Trigger 3 Pinhole for Cable Release (see page 3) 4 10-Pin RJ45, Female Socket 5 Beeper Hole 6 LED Indicator (see page 5) Figure 1. Scanner Components Maintenance Smudges and dirt on the unit’s window can interfere with the unit’s performance. If the window requires cleaning, use only a mild glass cleaner containing no ammonia.
Caution and Serial Number Labels Item Number, Serial Number and Compliance Information location. Figure 2. Label Location on the Bottom of the Scanner Caution: To maintain compliance with applicable standards, all circuits connected to the imager must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1.
Cable Installation and Removal Installation 1. Insert the cable’s modular connector into the socket on the scanner. 2. Pull gently on the cable strain relief to ensure the cable is installed. Figure 3. Removal Turn off power to the host system before removing the cable from the scanner. 1. Locate the small pinhole on the front side of the scanner near the end of the handle. 2. Bend an ordinary paper clip into the shape shown. 3.
Scanner Operation Audible Indicators When the scanner is operational, the scanner provides audible feedback to indicate the status of the scanner and the last scan. Eight settings are available for the tone of the beep (normal, six alternate tones and no tone). One Beep – On Power Up When the unit powers up, the green LED turns on, then the red LED flashes and the scanner beeps once. The red LED will remain on for the duration of the beep. The scanner is now ready to scan.
Visual Indicators The scanner is equipped with a red LED and green LED, which indicate the scanner’s state and the status of the current scan respectively when the unit is in operation. LED Figure 5. LED Location Green and Red LEDs Are Off The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. Steady Green Steady green indicates normal pulse or continuous laser operation.
Failure Modes One Razzberry Tone – On Power Up This indicates the scanner has experienced a laser or flipper subsystem failure. Return the unit for repair to an Authorized Service Center. Continuous Razzberry Tone with no LEDs If, upon power up, the scanner emits a continuous razzberry tone, then the scanner has an experienced an electronic failure. Return the unit for repair to an Authorized Service Center.
Troubleshooting Guide The following guide is for reference purposes only. Contact a customer service representative to preserve the limited warranty terms. Symptoms Possible Causes Solution All Interfaces No power is being supplied to the unit. The unit has no LEDs, beep or laser. No power is being supplied to the unit from host. Check the transformer, the outlet and power strip. Make sure the cable is plugged into the unit. Some host systems cannot supply enough current to power the scanner.
Symptoms Possible Causes Solution The unit powers up, but does not scan and/or beep. The unit is trying to scan a particular symbology that is not enabled. UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify the type of bar code being read has been selected. The unit powers up, but does not scan and/or beep. The bar code being scanned does not satisfy the configured criteria for character length lock or minimum length.
Symptoms Possible Causes Solution The unit scans but the data is not correct. The unit’s configuration is not correct. Make sure that the proper PC type AT, PS2 or XT is selected. Verify the correct country code and data format is selected. Adjust the inter-character delay symptom. The unit is transmitting each character twice. The unit’s configuration is not correct. Increase the interscan code delay setting. Adjust whether the F0 break is transmitted.
Design Specifications Operational Light Source: Visible Laser Diode (VLD) @ 650 nm Laser Power: Less than 1.0 mW average Depth of Scan Field: Scan Speed: Scan Pattern: Minimum Bar Width: 12.7 mm – 254 mm (0.5" – 10") 0.33 mm (13 mil) Bar Code 72 ± 2 scan lines per second Single scan line 0.1016 mm (4 mil) Decode Capability: Reads standard 1D and GS1 DataBar symbologies. System Interfaces: USB, Keyboard Wedge Print Contrast: No.
Electrical Input Voltage: Operating Power: Operating Current: DC Transformers: 5VDC ± 0.25V Standby: 700 mW Decoding USB: 975 mW Decoding KBW: 875 mW Standby: 140 mA average @ 5VDC Decoding USB: 195 mA average @ 5VDC Decoding KBW: 175 mA average @ 5VDC Class II; 5.
Configuration Introduction Your new scanner has been factory configured with a set of default parameters. Since many host systems have unique formats and protocol requirements, a wide range of configurable features that may be selected using this bar code based configuration tool are provided. Once the configuration is completed, the scanner stores the settings in nonvolatile memory (NOVRAM). NOVRAM saves the settings when the power is off.
Returning to Factory Defaults Scan the Recall Defaults bar code to erase all previous settings and return the scanner to its factory default communication protocol.
Code Types and Decode Rules Bar code descriptions marked with an asterisk ( * ) define a feature that is a factory default. Bar codes marked with a tilde ( ~ ) require the Multi-Code configuration method. 2 of 5 Codes ³ 9 0 1 6 0 0 ³ 9 0 1 7 0 0 ³ 9 0 3 4 0 0 ~ ITF Symbol Length Lock 1 – To specify a first ITF symbol length lock, scan this bar code and the appropriate code byte sequence located on page 23.
Supplements Enable Bookland (979) Supplement Required ³ 1 2 5 1 1 4 ³ 1 2 5 1 0 4 ³ 1 0 1 4 1 7 ³ 1 0 1 4 0 7 ³ 1 0 1 3 1 4 ³ 1 0 1 3 0 4 ³ 1 0 1 3 1 5 ³ 1 0 1 3 0 5 ³ 1 0 1 3 1 7 ³ 1 0 1 3 0 7 * Disable Bookland (979) Supplement Required Enable Bookland (978) Supplement Required * Disable Bookland (978) Supplement Required Enable 977 (2 Digit) Supplement Required – The scanner will require a 2 digit supplement to be scanned when an EAN-1
Scanner Operation Redundant Scans ³ 3 0 1 1 0 0 ³ 3 0 1 1 1 0 * 0 Redundant Scans – Requires 1 good decode for a good scan. 1 Redundant Scan – Requires 2 consecutive decodes of the same bar code data for a good scan. Data Transmission Delays Use these codes to select the amount of delay between sending data characters from the scanner to the host. This helps prevent the scanner from overflowing host-input buffers.
Prefixes/Suffixes Scan the Enter Configuration Mode bar code before trying to set these features (see the Multi-Code Method on page 12.) User Configurable Prefixes, All Data ³ 9 0 3 5 0 0 ³ 9 0 3 6 0 0 ~ Configurable Prefix Character #1 – A prefix ID can be added and assigned for data transmission. Use this code with a code byte sequence, on page 23, which represents the desired character. ~ Configurable Prefix Character #2 – Assigns a second configurable prefix character.
³ 1 1 6 6 1 0 ³ 1 1 6 6 0 0 ³ 1 1 6 6 1 4 ³ 1 1 6 6 0 4 ³ 1 1 6 6 1 6 ³ 1 1 6 6 0 6 ³ 9 4 1 6 0 0 Enable Tab Suffix – The scanner will transmit a TAB (ASCII 09H) after each bar code. * Disable Tab Suffix Enable ETX Suffix – The scanner will transmit End of TeXt (ASCII 03H) after the bar code date. * Disable ETX Suffix Enable UPC Suffix ID – The scanner will transmit a suffix after any UPC/EAN bar code.
Code Formatting UPC/EAN Formatting * Transmit UPC-A Check Digit ³ 1 0 7 5 1 7 ³ 1 0 7 5 0 7 ³ 1 0 7 5 1 6 ³ 1 0 7 5 0 6 ³ 1 0 7 5 1 5 ³ 1 0 7 5 0 5 ³ 1 0 7 6 0 2 ³ 1 0 7 6 1 2 ³ 1 0 7 5 1 0 ³ 1 0 7 5 0 0 ³ 1 0 7 5 1 4 ³ 1 0 7 5 0 4 Do Not Transmit UPC-A Check Digit Transmit UPC-E Check Digit * Do Not Transmit UPC-E Check Digit Expand UPC-E to 12 Digits – Expand UPC-E bar codes to the 12 digit equivalent, UPC-A bar codes.
³ 1 0 7 5 1 3 ³ 1 0 7 5 0 3 ³ 1 0 7 5 1 2 ³ 1 0 7 5 0 2 Transmit Lead Zero on UPC-E – This option will transmit a zero before each UPC-E bar code. Do Not Transmit Lead Zero on UPC-E Convert EAN-8 to EAN-13 – The scanner will transmit five zeros before the bar code to convert EAN-8 to EAN-13.
Keyboard Enable Keyboard Emulation ³ 9 9 9 9 9 4 ³ 5 1 5 5 1 4 Load Keyboard Wedge Defaults – Loads the default settings for keyboard wedge mode. 3 * Enable Keyboard Wedge Emulation – Use this with an external keyboard. Transmit in wedge made to allow standard PC keyboards to communicate when no bar code data is available.
ASCII (HEX) 22 ASCII Control Extended Key 00H Null Numeric Keypad + (Plus) 01H SOH Num Lock 02H STX Down Arrow 03H ETX Numeric Keypad - (Minus) 04H EOT Insert 05h ENQ Delete 06H ACK System Request 07H BEL (Right Arrow) 08H BS (Left Arrow) 09H TAB Tab 0AH LF Caps Lock 0BH VT Shift Tab 0CH FF Left Alt 0DH CR Enter 0EH SO Left Control OFH SI 10H DLE F1 Up Arrow 11H DC1 F2 12H DC2 F3 13H DC3 F4 14H DC4 F5 15H NAK F6 16H SYN F7 17H E
Code Bytes Usage The scanner must be in Configuration Mode for the features requiring code bytes for configuration. The Enter/Exit Configuration Mode bar code must be scanned before starting the configuration cycle. User configurable prefix/suffix characters can then be saved by scanning the 3 digit decimal equivalent of the ASCII character into the appropriate character location with the code byte bar codes. Example: To add an asterisk (*) as a Prefix, scan the bar codes. 1. 2. 3. 4. 5. 6.
Code Byte 8 ³ 8 ³ 9 Code Byte 9 Reserved Codes ~ Enable Reserved Code ³ 9 9 9 9 8 8 ³ 9 9 9 9 8 7 ~ Disable Reserved Code Code Type Table Code Byte 24 Code Types 004 UPC-A 002 UPC-E 003 EAN-8 005 EAN-13 080 Code 39 081 Codabar 082 Interleaved 2 of 5 083 Code 128 084 Code 93 091 MSI Plessey 092 Code 11 093 Airline 2 of 5 (15 digits) 094 Matrix 2 of 5 095 Telepen 096 UK Plessey 099 TRI-OPTIC 098 Standard 2 of 5 097 Airline (13 digits)
ASCII Reference Table HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 00 01 000 NUL @ 001 SOH A 02 002 STX B 03 003 ETX C 04 004 EOT D 05 005 ENQ E 06 006 ACK F 07 007 BEL G 08 008 BS H 09 009 HT I 0A 010 LF J 0B 011 VT K 0C 012 FF L 0D 013 CR M 0E 014 SO N 0F 015 SI 0 10 016 DLE P 11 017 DC1 Q 12 018 DC2 R 13 019 DC3 S 14 020 DC4 T 15 021 NAK U 16 022 SYN V 17 023 ETB W 18 024 CAN X
26 HEX Value Decimal Value/ Code Byte Value Character 1D 029 GS Control Keyboard Eqv ^ 1E 030 RS _ 1F 031 US space,blank 20 032 SP 21 033 ! 22 034 “ 23 035 # 24 036 $ 25 037 % 26 038 & 27 039 ‘ apostrophe 28 040 ( 29 041 ) 2A 042 * 2B 043 + 2C 044 , 2D 045 - minus 2E 046 .
HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 3C 060 < less than 3D 061 = 3E 062 > 3F 063 ? 40 064 @ 41 065 A 42 066 B 43 067 C 44 068 D 45 069 E 46 070 F 47 071 G 48 072 H 49 073 I 4A 074 J 4B 075 K 4C 076 L 4D 077 M 4E 078 N 4F 079 O 50 080 P 51 081 Q 52 082 R 53 083 S 54 084 T 55 085 U 56 086 V 57 087 W 58 088 X 59 089 Y greater than shift P letter l letter O 27
28 HEX Value Decimal Value/ Code Byte Value Character 5A 090 Z Control Keyboard Eqv 5B 091 [ shift K 5C 092 \ shift L 5D 093 ] shift M 5E 094 ^ à,shift N 5F 095 _ ♣, shift 0, underscore accent grave 60 096 ‘ 61 097 a 62 098 b 63 099 c 64 100 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 I 6A 106 j 6B 107 k 6C 108 l 6D 109 m 6E 110 n 6F 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119
HEX Value Decimal Value/ Code Byte Value Character 79 7A 7B 7C 7D 7E 7F 121 122 123 124 125 126 127 y z { | } ~ DEL Control Keyboard Eqv vertical slash alt mode (alt mode) delete, rubout Extended Key Code Reference Table Key Insert Delete Home End Page Up Page Down Right Alt Right Ctrl Reserved Reserved Numeric Keypad Enter Numeric Keypad/ F1 F2 F3 F4 F5 F6 F7 At Scan PS2 Scan Code Code 75H 72H 74H 6BH 70H 71H 6CH 69H 7DH 7AH 11H 14H 00H 00H 5AH 4AH 05H 06H 04H 0CH 03H 0BH 83H 48H 50H 4DH
Key At Scan PS2 Scan Code Code F8 0AH F9 01H F10 09H F11 78H F12 07H Numeric + 79H Numeric 7BH Numeric * 7CH Caps Lock 58H Num Lock 77H Left alt 11H Left Ctrl 14H Left Shift 12H Right Shift 59H Print Screen Multiple Tab ODH Shift Tab 8DH Enter 5AH ESC 76H Left ALT Make 11H Left ALT Break 11H Left CTRL Make 14H Left CTRL Break 14H *Left ALT + 1 character 11H *Left Crtl + 1 character 14H *Send Clear Jump Send Line Erase EOF Send - Make Only 42H 43H 44H 57H 58H 4EH 4AH 37H 3AH 45H 38H 1DH 2AH 36H 00H OFH 8F
Limited Warranty Seller warrants its products to be free from defects in materials and workmanship and to conform to seller’s published specifications applicable to the products purchased at the time of shipment.
All provisions of this Limited Warranty are separate and severable, which means that if any provision is held invalid and unenforceable, such determination shall not affect the validity of enforceability of the other provisions hereof. Use of any peripherals not provided by the manufacturer may result in damage not covered by this warranty. This includes but is not limited to: cables, power supplies, cradles, and docking stations. Seller extends these warranties only to the first end-users of the products.