Wireless module/GX-SEKONIC-A M odel GX-SEKONIC-A Users Manual Godox stamped 检证 批准 1 负责人
Table of Contents Chapter 1 Overview .......................................................................................................................................................................... 3 1.1 Scope of application................................................................................................................................................................ 3 1.2 Product overview ..............................................................................................
Chapter 1 Overview 1.1 Scope of application This specification describes the operation and handling of the following products. Customer name: SEKONIC CORPORATION Product name: Transmitted radio wave module model GX-SEKONIC-A Product code: GX Related Regulations: Radio Law, Specified Low Power Radio Equipment ARIB-T66 FCC 47CFR Part15.C, Canada RSS Gen/RSS 210 EU RE Directive 2014/53/EU, ETSI EN 300 440, EN62479 Environmental protection: Lead-free solder compatible SEKONIC SKGP 1.
CC2592 LNA- EN PA- EN CC2510 Wireless module MCU wit h RF Funct ion RF Cont rol USART Cont rol Port Cont rol Int errupt TxD RxD SYNC_IN# RESET READY CLEARTOSEND Exposure Met er microcomput er Above: Connect to the parent device with the 12-pin connector on the left side, and operate with the power supply (DC3V) from the parent device. The main connection signals are the trigger switch signal (SyncIn) and UART serial communication (3V).
Chapter 2 Appearance and structure 2.1 Appearance and dimensions This product is a printed circuit board module and has a structure in which electronic components such as semiconductors are soldered on one side of the circuit board, and a shield case for protecting the circuit components is soldered on it. The individual manufacturing number, the certification number for compliance with wireless regulations, etc. are displayed on the shield case.
Chapter 3 Electrical Specifications 3.1 Host connection interface This product is connected to the embedded master device with a 2.0 mm pitch/12-pin connector. The signals to be connected are as follows. Pi n f unct i on Si gnal r el i abi l i t y 1 +3. 3VDC Power s uppl y +3.
The connector on this product is 200-FH-1-12-43-S-28-24-GO-A (socket), and the square pin type header pin (product example: IK210SM-S12G-T15) is suitable as the parent device side connector. ・Power supply (1 pin) Input power supply voltage DC3.0V~3.6V, current consumption 0.09A maximum ・Trigger signal (3-pin) Active low (minimum 100uS width) transmission request signal. It sends a “TRIGGER” signal based on the preselected radio system specifications.
Chapter 4 Wireless Specifications 4.1 Physical specifications Minimum I t em Typical Maxi mum uni t 2412.999634 2464.499756 MHz Tr ans mi s s i on channel St ep 1.2 1.5 Fr equency s t abi l i t y -50 -0.5 +10 +4.0 MHz kHz Tr ans mi s s i on f r equency r ange Tr ans mi t out put power dBm dBi 0 Ant enna gai n 4.2 Protocol specifications This product has a mode compatible with two communication procedures of the system as the operation of wireless transmission.
Chapter 5 Internal Control The operation of the transmission wave module model GX changes as follows. "Start-up" After the power is turned on and the hardware is reset, the module initializes the internal circuits, outputs the module ID as a startup message to the UART interface, and then transitions to the idle state. "Idle" When the module is idle, it waits for a command from the UART interface, and if no command (or trigger signal) is received, there is no RF action.
Chapter 6 Embedded Specifications The transmission radio wave module model GX is designed to be used by incorporating it into the Seconic L-858-D exposure meter. It can be incorporated into other equipment, but it must meet the following conditions. 6.1 Mechanical conditions As shown in the figure below, the mechanical conditions for installing the module are as follows: (CON) must be mechanically adapted.
6.2 Electrical conditions (1) Connection of all functions in order to use all the functions of the module, connect the following signals. Pin function Signal reliability 1 +3.3VDC Power supply +3.
Chapter 7 Radio Compliance The transmission radio wave module model GX uses radio waves in the 2.4 GHz band and can be used in most countries and regions of the world without obtaining permission to use it wirelessly. It is necessary to comply with the relevant regulations. The transmission wave module model GX complies with the following laws and regulations. 7.
7.2 United States and Canada This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
Revision history Revision Page 0.1 All 0.2 6 0.